1. INSTALLATION ACCORDING TO THE EUROPEAN DIRECTIVE OF
ELECTROMAGNETIC COMPATIBILITY
SCA-05 servodrives can be installed in conjunction with external radiofrequency filters to
reduce electromagnetic Interference. These servodrives, when correctly installed, attend the
requirements of the electromagnetic compatibility directive "EMC Directive 89/336/EEC"
with the 93/68/EEC complement.
The SCA-05 series servodrive was developed only for professional applications. That is why
the harmonic current emission limits defined by the EN 61000-3-2 and EN 61000-3-2/A
14 standard do not apply.

1.1 Definition of the Standards

A table listing the standards that SCA-05 attends is presented below.
EMC Phenomenon
Emission:
Conducted Emission
("Main Terminal Disturbance Voltage"
Frequency Range: 150kHz to 30MHz)
Radiated Emission
("Electromagnetic Radiation Disturbance"
Frequency Range: 30MHz to 1000MHz)
Immunity:
Electrostatic Discharge (ESD)
Fast Transients ("Fast Transient Burst")
Conducted Immunity ("Conducted Radio-Fre-
quency Common Mode")
Surge Immunity
Radiofrequency Electromagnetic Field
Table 1 – Levels of emission and immunity attended
Basic Standard
IEC/EN61800-3
IEC 61000-4-2
IEC 61000-4-4
IEC 61000-4-6
IEC 61000-4-5
IEC 61000-4-3
Level
Depends on the servodrive model and
the length of the motor cable. See
table 2.
4kV discharge by contact and 8kV
discharge by air.
4kV/2.5kHz (capacitative coupler) input
cables;
2kV/5kHz control cables;
4kV/5kHz (capacitative coupler) motor
cable.
0.15 to 80MHz; 10V; 80% AM (1kHz);
Motor and control cables.
1.2/50µs, 8/20µs;
1kV line-line coupling;
2kV line-earth coupling.
80 to 1000MHz;
10V/m;
80% AM (1kHz).