1.4 Electrical Installation

The supply network must be connected to the filter input, on the side where information L1,
L2 and L3 are located. SCA-05 must be connected to the filter output, on the side where
information L1', L2' and L3' are located. The cables must be the shortest possible.
The Earth (PE) must be connected at the filter earthing point. SCA-05 must have its Earth (PE)
connected to the filter.
Only for SCA-05 24/48 Servodrives: A choke comes along with filter model B84143-A50-
R105 (used with the SCA-05 24/48). The cables of the SCA-05 supply phases must pass
through this choke, according to figure 3.
L1
L2
L3
Network
Figure 1 - Installation of the supply network in the SCA-05 4/8 and 5/8MF
Power Cable
Narrative
Power Cable, 4 wires,
Table 5 – CEM Kit for each servodrive model
CEM Kit for SCA-05 4/8 MF and SCA-05 5/8 MF
L1'
L2'
L3'
Description
03m (118.11in)
06m (236.22in)
09m (354.33in)
6mm²
12m (472.44in)
15m (590.55in)
Description
CEM Kit for SCA-05 4/8
CEM Kit for SCA-05 8/16
CEM Kit for SCA-05 24/48
Length
SCA-05
30/60
9