ERROR CODES
DESCRIPTION
Initial Zero is greater than allowed
(4% of maximum capacity) when
power is turned on or when the ZERO/
ENTER key is pressed.
Keyboard Error.
A/D count is not correct when turning
the scale on.
Can't set current weight as 100%.
Calibrate weight error.
Unstable, can't return to zero. (This
message only displays as scale is
powering on.)
CAUSES
Weight on the pan when turning the
scale on.
Excessive weight on the pan when
zeroing the scale.
Improper calibration of the scale.
Damaged load cell.
Damaged electronics.
Improper operation of the scale.
Platform not installed.
Load cell damaged.
Electronics damaged.
This message only shows when you
press '%' key in zero point.
Use of incorrect weight.
Verify that scale is on a stable
surface.
If scale was outside of operating
temperature range, allow ample
time for unit temperature to return to
acceptable range.