3. After setting the value of StEP, press both keys
simultaneously; the following message is dis-
played:
4. Use the right key to select YES or no
⇑
5. If YES is selected, press both keys simulta-
neously to end the programming. All parameters
set are saved.
⇑
⇑
6. The device is ready for operation.
4.2.2.1 The
in MAn Operating Mode
1. If YES was selected for
can show a value different from the value of the
output setpoint.
2.The SPecial disPlay function
A
SPecial disPlay Function
A
, the display
to
bei mA 24.00
to
bei mA 24.00
to
to
to
The function SPecial.decimalPoint
–
allows defining the number of decimal places
(only for the values appearing on the display).
display.Low allows defining the
–
minimum value to be displayed. This value corre-
sponds to the value ou.Lo used for the output
setpoint.
display.High allows defining the
–
maximum value to be displayed. This value
corresponds to the value ou.Hi used for the out-
put setpoint.
Example:
The display must show 10 (kg) while the setpoint
output must be 2 V (lower limit value); the display
must show 40 (kg) while the setpoint output must
be 8 V (upper limit value).
7
D
6
A
8 V
A
to
bei mA 24.00
2 V
to
10 kg
bei mA 24.00
to
3. Press both keys to resume programming at point
4.2.2 (1), SiGn see
⇑
⇑
Summary:
Display
Output value
When programming, the values for the display
and for the output setpoint are linked internally
together.
Note:
When the SPecial display function is activated, the
increment relates to the value scaled in the MAn
operating mode.
40 kg
in the flow chart
A
EN - Page 7