13. What if there are problems?
If the scale detects and error when measuring, the following is displayed.
Display
Ol
L0
eRR
No measurement possible
Possible errors
The scale was not activated before you stood on
it. If you step on the scale before " 0. 0 kg" is dis-
played, the scale will not work correctly.
The batteries in the scale are empty.
Incorrect weight measurement
Possible errors
Scale is on carpeting.
Incorrect zero point of scale.
Cause
The maximum load capacity of 150 kg
was exceeded.
The batteries are almost empty.
The electrical resistance between the
electrodes and the sole of your foot is
too high (e.g. if you have tough calluses).
The fat percentage is outside the meas-
urable range (less than 5% or greater
than 55%).
Remedy
Do not load the unit with over 150 kg.
Replace the batteries.
Repeat the measurement barefoot. If
necessary, moisten the soles of your feet
slightly. If necessary, remove the cal-
luses from the soles of your feet.
Repeat the measurement barefoot or, if
necessary, moisten the soles of your feet
slightly.
Remedy
Activate the scale correctly (wait for " 0. 0 kg") and
repeat the measurement.
Replace the batteries.
Remedy
Place the scale on a level and solid surface.
Activate the scale,
wait approximately 4 seconds,
repeat measurement.
17