Custom Settings - Monogram ZHU36RSPSS Manual Del Propietário

30 y 36 inducción electrónica estufa
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

USING YOUR COOKTOP

CUSTOM SETTINGS

1. Press and hold All Off pad for 3 seconds, then
immediately press and hold the Timer pad for 3
seconds to enter custom settings. Those two pads must
be pressed within 30 seconds. Any other pad will cancel
mode.
2. "C - -" appears on display. To navigate through the
Custom Settings, use the
(up) is selected the display cycle starts at "C01". If V
(down) is selected, the display cycle starts at "C62".
3. To activate a new Custom Setting the user will touch
and hold the Timer pad for 3 sec. Only ONE of the
Custom Setting Choices can be activated for each
Custom Setting. The red "On" LED will turn on and a
sound will go off once a new custom setting is activated.
4. The cooktop will exit Custom Settings if it is inactive for
3 minutes.
5. To exit Custom Settings and save any changes, touch
and hold the All Off pad for 3 seconds.
Custom Settings Chart
Custom Settings
C0 (Factory Settings)
C1 (Control Lock)
C2 (LED light level)
C3 (Button Loudness)
C4 (Timer Alarm Loudness)
C5 (Timer Alarm Duration)
* Options in grey are default settings
49-2000868 Rev. 0
(up) or V (down) pads. If
Custom Setting Choices
C01 - Factory Reset (Clears customized settings and restores defaults)
C02 - Custom settings activated (Not visible unless any other custom setting is selected. And automatically on
when any other custom setting is selected. Not selectable by user.)
C11 - Standard Lock (ie; Only on when lock button pressed for 3 seconds.) If using a timer, Control Lock is
unavailable.
C12 - Auto Lock (ie; Engages after cooktop has been in standby mode for 10 minutes.) The unit should be
completely off to go into Auto Lock.
C21 - Full illumination
C22 - Medium illumination
C23 - Lowest illumination
C31 - All sounds activated at 100% (For alarm sounds, 100% = Whatever level is set in c4.)
C32 - Button sound level reduced by 50%, Alarm sounds at 100%
C33 - Button sounds deactivated, Alarm sounds activated at 100%
C41 - High
C42 - Low
C51 - Indefinite (ie; alarm continues until cancelled by user).
C52 - Alarm sounds for 60 seconds.
C53 - Alarm sounds for 30 seconds.
C54 - Alarm sounds for 15 seconds.
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Zhu30rspssZhu36rdpbbZhu30rdpbb

Tabla de contenido