APPLICATION
Remove the lens cap from the objective lens (1).
We suggest that you do not open the lens cap when conducting
observation in the daytime at elevated illumination levels. The light
filter, built in the cap, reduces excessive image brightness and makes
observation more comfortable.
Activate the device by pressing the «ON» (2) button - the green LED (3)
will light up. If the battery is low the color of the indicator will turn red.
To turn off the unit, press the «ON» (2) again.
Locate an object within 20 to 30 meters.
Adjust image brightness by turning the adjustment wheel (4).
Brightness level from 0 to 20 is shown next to the icon
of the display and then on the data panel.
Note: on activation the device retains the function status before it was
turned off.
Rotate the eyepiece (5) and objective lens (1) until you see a sharp
image.
When changing the viewing distance, try to see a sharp and high-
quality image by rotating the objective lens (1) and brightness
adjustment wheel (4). Do not rotate the eyepiece (5) - the device has
already been individually adjusted.
To activate the 2x digital zoom, press the "Zoom" (10) button.
To increase range of detection and identification in low light conditions
or in complete darkness, you may switch on the built-in laser IR
Illuminator (6) by pressing the "IR" button (7). Press the "IR" button
successively to change power level (from 1 to 3). Respective icon
or
will appear on the display and data panel.
Keep the "IR" button pressed for two seconds to turn off the IR
Illuminator.
VIDEO OUT JACK
"Video out" jack (8) is designed to connect external recording devices
and to transmit video signal to monitors, TV sets etc.
Plug one jackplug of the video cable (supplied) into Recon's video
output (8) and the second jackplug (AV OUT) to an external device.
Turn on the device - an image will appear on the display of an external
device.
6
FUNCTION SUMLIGHT
The use of Sum Light™ substantially increases sensitivity of the CCD
array thus enabling observation in low light without using the IR
Illuminator.
The function is activated by default - icon
To turn off the function, press the "S" (9) button. Icon
data panel.
Attention! However please note that higher sensitivity causes an
increased noise level in the picture, lower frame rate; image slows
down, if the riflescope is rapidly moved from one side to the other,
in the upper part
the picture may be blurred for a moment. Neither of these effects is a
flaw of the unit. After the SumLight™ Signal Processing Program is
activated, light dots (pixels) may appear in the field of view which is
explained by operation peculiarities of this function. This is not a
defect either.
10
ACCESSORIES
The device is equipped with a special mount (11) that allows you to affix
various accessories, such as IR Flashlight, external power supply
(EPS3) , video recorder (CVR640) etc.
The unit also has a ¼" standard socket for installation on a tripod.
11
PECULIARITIES OF USE
Turn off the device when not in use and when carrying the unit.
The device can be used in daylight as well as nighttime conditions.
However, do not point the device towards bright sources of light.
After using the device in cold temperatures, please, wait up to 2-3
hours before using the device in the warm temperatures. This helps
prevent condensation on the lenses.
Do not leave the device in direct sunlight. Do not submerge in water.
Do not subject the digital NV device to shock or impact. Do not drop.
Sand, dust, and salt can damage the device.
Do not connect any non-recommended accessories (headphones,
for example) to the «Video out» port. This may damage the device
and void any guarantee.