Floors made of flammable material such as wood,
parquet, linoleum, laminate or floors covered
with carpets must be protected by a fireproof
base under the appliance that also protects the
front during cleaning from any falling burning
residues.
The manufacturer declines all responsibility for
any variations in the characteristics of the mate-
rial constituting the floor under the protection.
Set up an accessible technical space
for any maintenance work.
Remember to respect the minimum distance
from flammable materials (X), shown on the
identification plate of the pipes used to make the
chimney ( Fig. 13).
Pi = Flammable wall
Pp = Floor protection
54
Z
X2
Y1
Fig. 12
Y1
Y2
Z
200
200
600
mm
200
200
600
mm
Pi
X1
Pp
Set up the electricity supply line to arrive near the
appliance for the connection of the power cable.
6.4 Combustion air
The appliance, during its operation, requires
combustion air.
The inflow of combustion air can be obtained in
the following ways:
• it can come directly from outside with direct
connection to the combustion chamber (Fig.
14 - Fig. 15).
• it can come from the installation room or suita-
ble adjacent rooms (Fig. 16)
Extraction of combustion air from outside
In this case, a possible alternative may be:
• to channel the combustion air using a coaxial
exhaust pipe to expel the flue gases and extract
the air (Fig. 14 - A, B = Air inlet, C, D = Flue gas
outlet); in this case it is not necessary to create
a classic air intake in the room.
• to connect the combustion air inlet of the ap-
pliance to the air intake using a special pipe
(Fig. 15).