Important! The fitting must be installed, flushed
and tested after the valid norms!
Assembly
1
Flush through the supply pipes.
2
Place the mixer including the sealing
washer in position on the basin / bidet.
3
Slip the fixation piece including the washer
over the threaded pin and tighten the nut.
4
Connect the supply pipes to the isolation
valves;
5
cold right - hot left.
6
Connect the pull rod to the pop-up waste.
The hot and cold supplies must be of equal
pressures.
Technical Data
This mixer series-produced with
waterdimmer® (flow limiter).
Rate of flow with waterdimmer:
Rate of flow without waterdimmer:
Operating pressure:
Recommended operating pressure:
MPa
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
English
7 l/min 0,3 MPa
14 l/min 0,3 MPa
max. 1 MPa
0,1 – 0,5
1,6 MPa
max. 80° C
65° C
Hansgrohe single lever mixers can be used
together with hydraulically and thermically
controlled continuous flow heaters if the flow
pressure is at least 0,15 MPa.
If the continuous water heater causes any
problems or there is not enough flow of water,
the waterdimmer® (6a) located behind the
aerator must be removed.
Spare parts see page 3
1
flange
2
handle
3
cartridge cpl.
4
aerator
5
pull rod
6
connection hose
7
fixing set
8
extension hose300 mm
9
lever arm cpl. 290 mm
Special accessories
X special tool set 58085000
(order as an extra)
XXX = Colors
000 chrome plated
810 satinox®
96427XXX
10090XXX
96339000
94005XXX
94006XXX
96321000
94701000
13098000
96307000
5