CONVERSION INSTRUCTIONS
DRU-ART 2, 3, 4, 5, 6 /
STYLE 3, 4, 5
4. Adjusting the burner pressure
(fig. 1, page 20 / fig. 2, page 21)
Reconnect the gas pipe to the heater
and turn on the supply of new gas.
There is a point of pressure
measurement on the gas-control
block, which enables you to check
the burner pressure easily with a
manometer. Undo the screw at the
point of pressure measurement (4)
and connect the manometer.
For conversion to propane gas or
natural gas, the burner pressure is
adjusted with the pressure regulating
screw (2) as table, (pag. 17, 18 and 19).
DRU-ART 8-01, 10-01
4. Adjusting the burner pressure
(fig. 3, page 22)
Reconnect the gas pipe to the heater
and turn on the supply of new gas.
There is a point of pressure
measurement on the gas-control
block, which enables you to check
the burner pressure easily with a
manometer. Undo the screw at the
point of pressure measurement (4)
and connect the manometer.
For conversion to propane gas or nat-
ural gas, the burner pressure is adjust-
ed with the pressure regulating screw
(2) as table, (pag. 17, 18 and 19).
DRU-ART 2, 3, 4, 5, 6, 8-01,
10-01 / STYLE 3, 4, 5
5. Ignite the pilot light. Adjust the
thermostat to the highest setting and
adjust the burner pressure according
to the table.
Turn the burner off again, remove the
manometer and tighten the screw at
the point of pressure measurement.
DRU-ART 2, 3, 4, 5, 6, 8-01, 10-01 /
STYLE 3, 4, 5
6. Apply the new type plate.
Replace the casing over the heater.
10