Channel-to-Channel Failover

In addition to entire amplifier failover, Vocia supports channel-to-channel failover, which is triggered by one of the following conditions:
• Heat Sink fault
• Short Circuit fault
• Channel Failure fault
The wire failover link cable is not required when wiring channel-to-channel failover.
Parallel Wiring
2
1
The redundant channel can be wired in parallel to the existing speaker line (shown above) or connected to a redundant speaker line.
The primary amplifier module will resume control after the fault condition is cleared and the unit is re-powered.