Care and service

DANGER
Danger of electric shock
Injuries due to touching live parts
Switch off the device.
Remove the mains plug.
Dust extraction machines are safety devices for the
prevention or elimination of hazards according to
the German BGV A1.
 For servicing performed by the user, the device
must be disassembled, cleaned and main-
tained only to the degree that this is possible
without presenting a danger to the mainte-
nance personnel and other persons. Suitable
precautionary measures include detoxification
before disassembly. Make provisions for local
forced ventilation at the location where the de-
vice is to be disassembled, for cleaning the
maintenance surface and to ensure adequate
protection for the personnel.
 The exterior of the device should be detoxified
by vacuuming and wiped clean, or treated with
sealant before being removed from the hazard-
ous area. All unit parts must be regarded as
contaminated when they are taken from the
hazardous area. Suitable measures must be
taken to prevent distribution of the dust.
 All contaminated objects resulting from mainte-
nance and repair work that cannot be satisfac-
torily cleaned must be correctly disposed of.
Such objects must be disposed of in sealed
bags in accordance with the applicable regula-
tions for the disposal of this type of waste.
DANGER
Danger from dust that is harmful to your
health
Respiratory sicknesses through inhala-
tion of dust.
Wear a breathing protection mask of class P2 or
higher and disposable clothing when performing
maintenance work (e.g. filter change).
18
WARNING
Danger from dust that is harmful to your
health
Respiratory sicknesses through inhala-
tion of dust.
Safety devices providing hazard protection must
be checked for correct safety-related functionality
at least annually by the manufacturer or an appro-
priately instruction person, e.g. absence of leaks,
filter damage, functionality of the monitoring devic-
es.
ATTENTION
Care agents containing silicone
These can attach plastic components.
Do not use care agents containing silicone for
cleaning.
 You can perform basic maintenance and care
work yourself.
 The surface of the device and the interior of the
container should be regularly cleaned with a
moist cloth.
ATTENTION
Clogged ventilation slits
Risk of damage to the suction motor.
Keep the device and ventilation slits clean to en-
sure good and safe working conditions.
 Should the vacuum cleaner fail despite our thor-
ough manufacturing and testing procedures, re-
pairs are to be performed by a Würth Master
Service.
You can contact Würth Master Service free of
charge in Germany via 0800-WMASTER
(0800-9 62 78 37) or in Austria via 0800-20
30 13.
 For all queries and spare part orders, always
state the item number according to the type
plate of the vacuum cleaner.
Replacing the flat fold filter
1. Open the filter cover.
2. Remove the filter frame.
Figure G
3. Remove the flat fold filter.
4. Dispose of the used flat fold filter in accordance
with statutory regulations.
5. Remove any dirt deposits from the clean air side.
English