Oil Table - Annovi Reverberi HJK 13.12 H Manual De Uso E Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Proceed as described to replace the oil in piston pumps.
1) Prepare a suitable capacity container.
2) Unscrew the plug (B).
3) Unscrew the plug (A) and let all the oil drain out.
4) Clean the plug (A), fitted with a magnet, of any ferrous
residue produced from operating the electric pump.
5) Screw the plug (A) back into place.
6) Pour in fresh oil until the correct level is reached
(see "Checking the oil level").
7) Screw the plug (B) back into place.
Refer to the "Oil Table" for the oil characteristics.
Proceed as described to replace the oil in wobble-plate
pumps.
1) Prepare a suitable capacity container.
2) Unscrew the plug (C).
3) Unscrew the plug (D), if present, and let all the oil
drain out.
4) Screw the plug (D) back into place.
5) Pour in fresh oil until the correct level is reached (see
"Checking the oil level").
7) Screw the plug (C) back into place.
Refer to the "Oil Table" for the oil characteristics.

Oil Table

Never mix oils of different origins together.
The electric pump is delivered complete with oil, with
the characteristics stated on the data plate.
When changing the oil, use an oil suitable for
the
conditions
in
the
-35
-30
-25
-20
M2010_16_322-CV
English
MAINTENANCE INSTRUCTIONS
operating
environment
-15
-10
-5
0
SAE 10W
SAE 20W
SAE 10W-30
SAE 10W-40
SAE 15W-40 mineral base
SAE 15W-40 semi synthetic base
SAE 20W-60 semi synthetic base
SAE 5W-30 synthetic base
SAE 0W-30 synthetic base
Piston electric pump
B
Wobble-plate electric pump
UN004364-DL
(see recommendations provided in the annexes and see
"Environmental operating limits").
The correct lubricating oil viscosity depends on the
external temperature.
+5
+10
+15
+20
+25
SAE 30
SAE 10W-60
45
+30
+35
+40
+45
SAE 40
Use and Installation
7
D
+50

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hjk 15.15 hHjk 21.15 h

Tabla de contenido