Gewiss JOINON Serie Manual De Instalacion Y Uso página 76

Ocultar thumbs Ver también para JOINON Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 131
Gewiss
Code
Error description
The residual current circuit
breaker of the relative type 2
socket-outlet/side is OFF.
Error 3
NB: error not managed on the
WallBox version
The contactor is working when
it shouldn't be. The Type 2
Error 4
socket-outlet is powered in the
standby condition
The shutters of the type 2
Error 5
socket-outlet aren't in the right
condition (closed)
76
Solution
Restore the correct operation
of the residual current circuit
breaker. If the error persists,
replace the device.
For I-ON columns with Restart,
disconnect the vehicle from
the column and make sure the
signalling is automatically reset.
If the error persists, this means
that Restart has detected an
insulation fault in the circuit
inside the column; check the
circuit between the residual
current circuit breaker and
the contactor.
Check the signal from the
electronic board to the
contactor, to make sure
the former isn't controlling
the latter. If the board isn't
controlling the contactor, make
sure the contactor contacts
aren't jammed.
If necessary, replace the device.
Check the mobility of the gates
and the relative mechanical
devices. If necessary, replace
the socket-outlet.
Faults and troubleshooting
Position
7.55.4.515.2 - Installation and Operation Manual