Hansgrohe Ecostat 1001 SL 13241 Serie Manual De Montaje página 9

Ocultar thumbs Ver también para Ecostat 1001 SL 13241 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
Fault
Insufficient water
Crossflow, hot water is forced
into cold water pipe, or vice
versa, when mixer is closed
Spout temperature does not
correspond with the
temperature set
Temperature regulation not
possible
Shower or spout dripping
Instantaneous heater didn't
work with thermostat
English
Cause
-
Supply pressure inadequate
14
-
Filter are dirty (
)
-
Shower filter seal dirty
- Backflow preventers dirty or
leaking
-
Thermostat has not been
adjusted
-
Hot water temperature too low
- MTC-thermo cartridge calcified
- Dirt or sedimentation on valve
seat, shut-off unit damaged
-
Ecostop ring isn't removed
-
Flow limiter in handshower isn't
removed
-
Filter are dirty
-
Non return valve didn't move
back
Remedy
-
Check mains pressure
-
Clean filter in front of the mixer
and on the MTC-thermo
14
cartridge (
)
-
Clean filter seal between
shower and hose
- Clean backflow preventers,
exchange if necessary
-
Adjust thermostat
-
Increase hot water temperature
to 42 °C to 65 °C
- Exchange MTC-thermo
cartridge
- Clean or exchange shut-off unit
-
Remove ecostop ring (12)
-
Remove flow limiter
-
Clean the filter/exchange filter
-
Exchange non return valves
9

Publicidad

Tabla de contenido
loading

Tabla de contenido