Temperature Limitation; Technical Data - Hansgrohe Ecostat 1001 SL 13241 Serie Manual De Montaje

Ocultar thumbs Ver también para Ecostat 1001 SL 13241 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
Assembly
The fitting must be installed, flushed and
tested after the valid norms!
1. Flush through the supply pipes.
2. Mount the S - unions and align them.
3. Fasten the mixer with the washers.
Large differences in pressure between the hot and
cold water supply should be balanced.
Adjustment
Correction is necessary if the temperature
measured at the take off point differs from the
temperature set on the scale. To adjust please see
page 20.
Operation 13241XXX
By turning the handle on the left hand side the
thermostatic mixer is opened, closed and the flow
can be changed from tub to shower function.
The temperature is selected by turning the
graduated handle on the right side.
Operation 13261XXX/13266000/
13278000
The mixer is operated by turning the handle on the
left hand side. The green knob limits the rate of
flow to approx. 10 l/min. If a higher water
consumtion is required press the ECOSTOP button
and turn handle further.
The temperature is selected by turning the
graduated handle on the right side.

Temperature limitation

The temperature is limited by the safety check to
38° C (100° F). If a higher temperature is required,
it is possible to override the safety stop by
depressing the safety button.
To garantee a smooth running of the thermoelent, it
is necessary from time to time to turn the thermostat
from total hot to total cold.
Attention!
The mixer is equipped with non return valves.
The non return valves must be checked regularly
according to DIN EN 1717 in accordance with
8
English
national or regional regulations (at least once a
year).
Using the 13261XXX/13266000/
13278000 in conjunction with
combination boilers.
When using the Ecostat with combination boilers,
the Ecostop ring 12 has to be removed (please see
page 22).
If fitting a hand shower remove the water limiter
from the shower.
Using the 13241XXX in conjunction with
combination boilers.
If fitting a hand shower remove the water limiter
from the shower.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 3 bars:
Anti-pollution function
Spare parts (see page 3)
1
thermoelement
2
shut off and diverter unit
3
knob for thermoelement
4
knob for shut off and diverter unit 96619XXX
5
aerator cpl.
6
non return valve
7
noise reduction
8
s-unions
9
escutcheon
10 safety set for temperature control 95041000
11 shut off unit
12 safety set for flow control
13 filter packing
XXX = Colours
000 chrome
800 steel
810 satinox
max. 10 bars
1 - 5 bars
16 bars
max. 80° C
65° C
20 l/min
94282000
96509000
96618XXX
13485000
96737000
96429000
94140000
96467XXX
94149000
95042000
96922000

Publicidad

Tabla de contenido
loading

Tabla de contenido