Clean Main Filter Basket; Replace Motor Protection Filter; Troubleshooting; Suction Capacity Decreases - Würth TSS 7-L BASIC Traducción Del Manual De Instrucciones De Servicio Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
WARNING
Safety equipment for preventing haz-
ards must be serviced and maintained
regularly. This means that the manufac-
turer's staff or persons trained by the
manufacturer must check the equipment
for proper functioning at least once a
year, i.e. check for leaks, filter damage,
etc.
ATTENTION
Risk of damage! Do not use detergents
containing silicone to clean.
No outside help is required for carrying out
basic maintenance and cleaning.
The appliance surface and the inside of the
container should be cleaned regularly using a
damp cloth.
DANGER
Risk due to dust hazardous to health. Al-
ways use disposal clothing and P2 or
higher breath-safe masks while carrying
out maintenance tasks (such as changing
filters).

Clean main filter basket

 Main filter basket (washable), clean it under
running water if necessary.
ATTENTION
Risk of damage! Never insert the main
filter basket while wet.

Replace motor protection filter

Replace the motor protection filter every
three months for daily use; replace as
needed if severely contaminated.
 Release and remove the suction head.
 Remove the motor protection filter.
 Insert new motor protection filter.
 Insert and lock the suction head.

Troubleshooting

DANGER
First pull out the plug from the mains be-
fore carrying out any tasks on the ma-
chine.
Note: In case of a failure (e.g. filter breakage) the
appliance must be turned off immediately. The fail-
ure must be remedied before the appliance is put
into operation again.
The appliance shuts off during the
operation
Motor thermal protector has responded.
 Replace fleece filter bag.
 Replace motor protection filter.
 Check all parts for plugging.
Switching back on after the motor turbine has
cooled off, after approx. 30 to 40 minutes.
Suction turbine does not run
 Check the receptacle and the fuse of the pow-
er supply.
 Check the power cable and the power plug of
the device.
 Turn on the appliance.

Suction capacity decreases

 Remove choking of suction nozzle, suction
tube or suction hose.
 Replace fleece filter bag.
 Clean the main filter basket under running wa-
ter.
 Insert/lock the suction head correctly.
 Replace defective suction hose.
 Replace motor protection filter.
 Insert main filter basket to establish a sealing
effect between dirt receptacle and the suction
head.
GB - 4
15

Publicidad

Tabla de contenido
loading

Tabla de contenido