OPERATING INSTRUCTIONS
Directions for use
1. Turn on by pressing the power control.
2. Select fan speed. Low speed, white light. High speed, orange light.
3. Select UVC, a blue light indicates it's on.
4. Nightlight will be off when powered on, to turn on, hold UV-C control button for 5 seconds.
Essential Oil Option
1. A replaceable aroma pad is included in the
aroma tray on the back of the unit.
2. Remove the tray cover.
3. Remove the oil pad and add a few drops
of an essential oil – more or less may be
used depending on your aroma strength
preference.
4. Replace the oil pad and tray cover onto the unit.
Charging Instructions
The power control will be slow pulsing red when the battery drops below 25% and needs charged.
To charge plug the USB cord into the charging port on the purifier and the other end into a USB wall
charger or charging port on a computer, in a car, etc. As the battery becomes charged the power
control light will change to a flashing white then a solid white when 100% charged. The unit will run
for approximately 1 hour and 40 minutes on high speed with UV on, and up to 8 hours in low speed
with UV off.
Filter Replacement
The power control will turn to a solid red
indicating that it is time to replace the filter.
Replace the filter according to the directions
then press the power button and hold for 5
seconds to restart the system. Depending on
usage the filter will last approximately 6-8 months.
REPLACE FILTER
1. Turn off the unit.
2. Twist the filter base on the bottom of the purifier
counterclockwise to unlock.
3. Remove filter and replace with a new one.
4. Reattach the filter base by twisting clockwise to lock.
5. Push and hold the power button for 5 seconds to reset the filter change indicator.
CHECK AND MAINTAINING FILTER
Maintain the filter by checking it frequently.
Depending on air conditions you may need to replace it more often.
IMPORTANT: Do NOT try to wash and re-use the filter
IMPORTANT: Use Guardian Technologies GENUINE Replacement Filter only.
NOTE: The purifier is equipped with a UV-C LED. This is not a serviceable or replaceable part.
E-6

TROUBLESHOOTING GUIDE

PROBLEM
SOLUTION
Unit fails to power on or
Battery power is too low. Use the power charger to recharge the unit.
shuts off unexpectedly.
Ensure purifier speed setting is selected.
Unit is damaged or in need of repair. Cease usage and unplug.
Contact Guardian Customer Service for assistance.
Power indicator is
There is less than 25% battery left. Use the power charger to recharge
flashing red.
the unit. If the unit powered off due to low battery and is not charged,
when turned on again it will rapidly flash red as a reminder to charge
the unit.
Unit is charging but the
As the battery becomes charged the power indicator light will change
lights are flashing white.
from a flashing white to a solid white when it is 100% charged.
Battery fails to get charged.
Ensure the specified power charger is used.
The outlet is worn or damaged. Try another outlet.
USB port fails to charge
Check battery power status. If battery power is too low, use the
digital devices.
power charger to recharge.
If otherwise, contact Guardian Customer Service for assistance.
No air circulating from unit.
Check filter.
Increase in noise level.
Replace if necessary.
Power light turns to a
Replace filter and reset system.
solid red.
Make sure filter is clean. Replace if necessary.
Replaced filter and red
After replacing the filter, press the power button and hold for
light is still blinking.
5 seconds to restart the system.