- Press the boiler cap (9) downwards and turn it
anticlockwise at the same time, so as to unscrew
it completely.
- Pour a suitable amount of water (min. 0.5 l, max.
1.6 l) using the provided jug and funnel.
- Put the cap on the boiler: press it downwards and
turn it clockwise at the same time, so as to screw
it tight.
•WARNING!
• Make sure that the boiler cap is properly closed.
Cap loosening during use may cause scalds!

Connecting the steam cleaner

DANGER!
(fig. C)
• Connect the machine only if the mains voltage
matches to the rated voltage marked on the
rating plate.
• The main switch (4) must be disconnected (OFF
position).
• The power cord (10) must not be damaged.
• The water tank must be filled with a sufficient
water quantity (min. 0.5 l) using the special
measuring jug.
• The hose must be connected to the relevant
accessory.
• The steam nozzle must not be obstructed.
- Press the main switch (4); the indicator lights (4/B
and 5) come on (heating begins).
- The machine is in operation.
- Water is heated and steam is generated.
- When the green lamp lights up (3) the machine is
ready to work.

Pouring water into the boiler

WARNING!
• When the machine is in use, don't open the boiler
cap (9)! Danger of scalds!
NOTE:
• When the boiler water is finished, the orange
water indicator lamp (6) will light up.

Filling

• After the orange "no water" light (6) comes on,
54
make sure that the machine no longer supplies
steam (keeping the control device (12) open) by
repeatedly activating the steam lever (1).
• Disconnect the main switch (4) (OFF position).
• Remove the electrical plug (10) from the supply
socket.
• Let the steam cleaner cool down until the index
reaches the yellow area.
• Press the boiler cap (9) downwards and turn it
anticlockwise at the same time, so as to unscrew
it completely.
• Pour water into the boiler.
• Put the cap (9) on the boiler: press it downwards
and turn it clockwise at the same time, so as to
screw it tight.

Disconnecting the steam cleaner

• Disconnect the main switch (4) (OFF position).
• Pull out the electrical plug (10) from the supply
socket.
• Let the steam cleaner cool down.

ACCESSORIES' APPLICATION

Fitting or removing accessories
•DANGER!
• Never work with wet hands. Electric current:
Danger of death!
• The steam cleaner must be disconnected before
removing the accessories.
• Accessories get hot
working. Let them cool down before carrying out
any replacement. Be careful when replacing the
accessory during operation: danger of scalds.
Fit the extension pipe
• Press the spring button (18) on the steam nozzle
handle (19)
• Fit the steam nozzle handle (19) into the sleeve
of the extension pipe (17) until the spring button
(18) snaps into place.
Fitting the brushes
(fig. D)
• In order to be able to use the rectangular or the
when the machine is