STRUCTURE OF THE MAIN MENU

3sec
The Set up menu allows choosing:
The Language, the display contrast, the safety Password, the activation or deactivativation of the Enable input (dosing
enable) and of the peristaltic hose breaking sensor.
The Dosage menu allows choosing:
the type of dosing among Manual, Proportional and ON-OFF.
The Calibration menu allows:
Calibrating the chlorine probe.
The Utility menu allows choosing:
to schedule or not the Delay On, the overdosage TAL alarm, the type of functioning of the flow sensor and finally to
Restore the factory programming of the parameters and the factory probe calibration.
The Relay menu allows choosing:
the operation of the alarm relay (N.O or N.C), whether to include or exclude from the relay signal the various types of alarm
(Delay On, TAL, Flow, UR-OR, Stand by, Level, Enable, Hose break.).

MENU SET UP

IMPORTANT NOTE:
Enable and Brok. Hose sensor are optional. If on your pump they are not present you can not access the
respective submenus and in the menu will appear:
3sec
Rev 1.1
Press the ENTER / MENU button for 3 seconds to enter
programming.
Use the ▼ button to move the cursor to the relevant
submenus. Press ENTER to enter the submenu.
If you want to esc programming and return to measurement,
press the ESC button for 3 seconds.
Press the ENTER/MENU button for 3 seconds to enter
programming.
Select by the cursor the menu SET up and press ENTER.
Use the ▼▲ buttons to move the cursor to the submenus.
Press ENTER to enter the submenu.
If you want to esc programming and return to measurement,
press the ESC button for 3 seconds.