Regulatory Information; Contact Information - Interlogix Advisor Advanced ATSx500A Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
Change the area name in 4.2.n.1 Area name.
01 Area name
>Area 1
<
Configure other options of the area:
4.2.n.2 Exit time
4.2.n.3 Entry time, etc.
Caution:
Before enabling 4.2.n.8 Dual unset, make sure to
add users that can assist the unset. See "Adding users" above.
Configuring Central Station
Configure the communication path in 9.3 Path options.
1>PSTN
3 GSM/SMS/GPRS
Select the required path and configure it depending on the
hardware used.
Next, go to menu 9.1 Central station.
0>Add CS
1 CS 1
Add a new CS, or choose an existing one. Configure the
following parameters:
9.1.n.1 CS name
9.1.n.2 Transm path
9.1.n.3 Protocol
9.1.n.5 Accounts
Other options, depending on the communication path
used.
Test the communication using menu 1.2.6.n.6 Man. test call,
where <n> is the number of the configured Central Station.
Calling CS 1...
Ready
Regulations
If necessary, follow the instructions given in the "Regulations"
chapter of Advisor Advanced ATSx500A(-IP) Installation and
Programming Manual to configure other options, required by
the appropriate standards and norms.
Other manuals
See Advisor Advanced User Guide for more information on
how to use the Advisor Advanced system.
See Advisor Advanced Manager Manual for more information
on system management.
See Advisor Advanced Installation and Programming Manual
for more information on system configuration and
programming.
See Advisor Advanced SMS Control Reference Manual for
more information on SMS commands.
4 / 42
Enter a new area name

Regulatory information

Manufacturer
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Certification
Warnings and
These products are intended for sale to, and
Disclaimers
installation by, an experienced security
professional. UTC Fire & Security cannot provide
any assurance that any person or entity buying its
products, including any "authorized dealer," is
properly trained or experienced to correctly install
security related products.
For more information on product warnings, refer
to www.utcfssecurityproducts.eu/productwarning/
or scan the code.
EN 50131-1 System requirements
EN 50131-3 Control and indicating equipment
EN 50131-6 Power Supplies
EN 50136-1-1 Alarm systems -Alarm
Transmission systems
ATS1500A(-IP): Security Grade 2, Environmental
class II
ATS3500A(-IP): Security Grade 3, Environmental
class II
ATS4500A-IP: Security Grade 3, Environmental
class II
Note:
ATS1500A(-IP) is upgradable to Security
Grade 3 using the ATS-MM-TK (MM enclosure) or
the ATS-SM-TK (SM enclosure) tamper kit.
Tested and certified by VdS Schadenverhütung
GmbH
Important:
it is required to configure the system according to
settings listed in Advisor Advanced ATSx500A(-
IP) Installation and Programming Manual,
chapter "Regulations".
This product has
with EN 50134 and EN 54 norms.
UTC Fire & Security hereby declares that this
device is in compliance with the applicable
requirements and provisions of the Directive
2014/30/EU and/or 2014/35/EU. For more
information see www.utcfireandsecurity.com or
www.interlogix.com.
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.utcfssecurityproducts.eu/recycle/

Contact information

www.utcfireandsecurity.com or www.interlogix.com
For customer support, see www.utcfssecurityproducts.eu
P/N 466-2523 (ML) • REV D • ISS 16JUN17
To comply with the above standards,
not
been designed to comply

Publicidad

Tabla de contenido
loading

Tabla de contenido