Safety notes
• Installation is only pemissible in frost-free rooms.
• The plug-in connectors must not be directly or indirectly
sprayed with water when cleaning.
Application
Can be used in conjunction with:
• Pressurised storage heaters
• Thermally controlled instantaneous heaters
• Hydraulically controlled instantaneous heaters
Operation with unpressurised storage heaters (displacement
water heaters) is not possible.
Technical data
• Flow pressure:
– min.
– recommended
• Operating pressure
• Test pressure
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Avoid major pressure differences between hot and cold water
supply.
• Max. flow
6.6 L/min or 1.75 gpm / 0.41 MPa
• Hot water supply temperature:
• Recommended (energy saving):
• Ambient temperature:
• Relative air humidity:
• Voltage supply:
• Rated power:
• Automatic safety shut-off after touch:
• 3 water pulses indicate discharged battery.
• Control type of protection:
• Water connection
Installation
Refer to the hose lengths and installation dimensions on fold-
out page I.
Caution: The control should be easily accessible to trigger
cleaning mode.
Flush piping system prior and after installation of faucet
thoroughly!
Install faucet, see fold-out page II, Fig. [1] to [5].
Connect faucet
EasyTouch with cold water, see Fig. [6].
In combination with a special accessory, see replacement
parts on fold-out page I, Prod. No. 34 507, the faucet can also
be used with premixed water.
EasyTouch with mixed water, see Fig. [7].
1
English
0.05 MPa
0.1 - 0.5 MPa
max. 1.0 MPa
1.6 MPa
max. 176 °F
140 °F
39 – 104 °F
max. 80%
6V lithium battery (type CR-P2)
1.4 W
60 s
IP 44
cold - right (T-connector)
hot - left
Install and connect holder with control, see Fig. [8] to [11].
Attach weight to shower hose, see Fig. [12].
When using metal sinks, the sink must be connected to
the control for potential equalisation using the enclosed
cable in order to ensure function, see Fig. [13].
For all other sinks the cable has to be connected to another
suitable metal part for potential equalisation, e. g. service
valve.
Insert battery, see fold-out page III, Fig. [14].
Open hot and cold water supply and check that
connections for leakage.
Operation/commissioning
To avoid water damage, ensure the spout is
always positioned over the sink and ensure
free draining.
Operation, see fold-out page III, Fig. [15].
Cold water can be drawn without operating the lever by
touching the grey areas with your hand.
Caution: Triggering only through skin contact.
The spout can be swivelled by the white mouthpiece without
triggering the faucet.
31 359: Shower jet diverter, see Fig. [16].
Flow rate limitation, see Fig. [17] and [18].
Cleaning mode, see Fig. [19].
Cleaning mode is activated by pressing the AQUA STOP
button:
• Confirmation by a water pulse.
• In cleaning mode, the indicator lamp flashes 2x.
• Cleaning mode ends after 2 minutes.
Adjusting the sensitivity, see Fig. [19].
The sensitivity of the triggering varies depending on the
ambient temperature and humidity. The sensitivity can be
adjusted in 5 steps. The control is set to step 3 at the factory.
The menu is activated by pressing the AQUA STOP button for
at least 10 seconds:
• The indicator lamp flashes 1x.
• The last saved value is then indicated by the number of
flashes, e. g. 3x for step 3.
• Each additional press increases the sensitivity by one step.
• If the button is not pressed, the indicator light flashes 1x and
the menu is exited. The last set value is stored.