Thank you for buying the PS12015. Read this manual carefully before bringing the device into service. Make sure
that the device was not damaged in transit. If the device is damaged, don't use it and contact your dealer.
2. Technical Specifications
Input Voltage
Output Voltage
Output Current
Ripple & Noise
Supply Regulation
Load Regulation
Accuracy Voltage
Protection
Operating Temperature
Operating Humidity
Operating Atmospheric Pressure
Dimensions (L x W x H)
Weight
Fuse
3. Front Panel & Operation
1. Voltage indication
2. Black = negative (-) output terminal
3. Red = positive (+) output terminal
4. ON/OFF LED
5. ON/OFF switch
6. Voltage adjustment knob
Connect the device to the mains, switch it on
(#5, LED #4 lights up), adjust the voltage (#6) to
the desired level and connect the desired load.
Mind the polarity.
If the device shouldn't power on, check (and
replace) the fuse at the back. If the device still won't power on, have it repaired by a qualified technician.
4. Notes
- For more accurate voltage reading, connect an external high accuracy meter.
- This unit is short circuit protected. If a short circuit should occur, turn the power supply off and solve the problem.
- Install or store the device in a clean and well-ventilated environment.
- Do not try to open the housing yourself. All repairs should be executed by a qualified technician.
- Disconnect the unit from the mains before maintenance and when it will not be used for a long time.
- The unit can get very hot when you are using a high power output.
- If the unit is defective, the output may exceed the maximum rated voltage. Always keep an eye on the load to
prevent damage.
- This device should be earthed properly.
The information in this manual is subject to change without prior notice.
PS12015
PS12015 - - DC-REGULATED POWER SUPPLY
: AC 230V ±10% ; 50Hz ±2Hz
: 1.2-12V continuously adjustable
: 1.5A
: CV ≤ 2.0mVrms
: CV ≤ 1x10
: CV ≤ 5x10
: ±1% ± 2 digits
: current-limiting
: 0 - 40°C
: <RH80%
: 86kPa ~ 104kPa
: 115 x 80 x 190mm
: 1.8kg
: 220V, 0.5A (order code FF0.5N)
+0.5mV
-4
+2mV
-4
1
VELLEMAN

Publicidad

Tabla de contenido
loading

Resumen de contenidos para HQ-Power PS12015

  • Página 1 1. Introduction Thank you for buying the PS12015. Read this manual carefully before bringing the device into service. Make sure that the device was not damaged in transit. If the device is damaged, don't use it and contact your dealer.
  • Página 2: Technische Specificaties

    PS12015 - - REGELBARE DC LABORATORIUMVOEDING 1. Inleiding Dank u voor uw aankoop! Lees deze handleiding aandachtig voor u uw PS12015 in gebruik neemt. Als het toestel werd beschadigd tijdens het transport, gebruik het dan niet en raadpleeg uw dealer.
  • Página 3: Spécifications Techniques

    PS12015 - - ALIMENTATION CC REGLABLE 1. Introduction Nous vous remercions de votre achat ! Lisez le manuel attentivement avant de prendre votre PS12015 en service. Si l’appareil a été endommagé pendant le transport, ne l'utilisez pas et consultez votre revendeur.
  • Página 4: Introducción

    PS12015 - - FUENTE DE ALIMENTACIÓN CC REGULABLE 1. Introducción ¡Gracias por haber comprado la PS12015! Lea cuidadosamente las instrucciones del manual antes de montarlo. Verifique si el aparato ha sufrido algún daño en el transporte antes de la puesta en marcha. Si es el caso, no conecte el aparato a la red y póngase en contacto con su distribuidor.
  • Página 5: Technische Daten

    PS12015 - - DC-LABORNETZGERÄT 1. Einführung Danke für den Kauf des PS12015. Bitte lesen Sie vor Inbetriebnahme diese Bedienungsanleitung sorgfältig durch. Überprüfen Sie, ob Transportschäden vorliegen. Sollte dies der Fall sein, verwenden Sie das Gerät nicht und wenden Sie sich an Ihren Händler.

Tabla de contenido