INSTALLATION AND CONFIGURATION

CONFIGURATION MENU

Once the unit is connected, follow the next procedure to access the configuration menu:
1. To Access the configuration menu, press and hold both the SET and ENTER buttons simultaneously until the display
shows "LOCAL SETUP"
2. Then, "ADD" is displayed on the screen to indicate that the local address can be set. Automatically a counter is
displayed. The count is incremented from one to 126. When the desired address number is displayed, press ENTER
to confirm the number. If you want to reset the counter, press SET.
3. Once the address is confirmed, "E.O.L" is displayed on the screen to set the end of line resistor. "ON" (led "E.O.L"
on) or "OFF" (led "EOL" off) is displayed according to the last saved status. To change the status, press the "SET"
button and then press ENTER to confirm.
4. "MODE" is displayed on the screen to set the display mode during a transaction. To change the mode, press SET
until the desired mode, "STD" (standard) or "XXL" are displayed. Once the mode is set, press "ENTER" to confirm.
5. "OK!" is displayed on the screen and the unit restarts showing the standby screen.
PAIRING WITH A U·VISION UNIT
This unit is equipped with a wireless connection so that it can be paired with a U·Vision or U·Vision+ gun.
Consult the U·Vision instruction manual for further information.
LED AND DIAGNOSTIC INDICATORS
In the "standby" mode, the firmware version installed on
the unit and the supply voltage are displayed on the
screen by pressing the "SET" or "ENTER" button.
1
6
838 849 R. 06/18
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
2
3
4
LED
DESCRIPTION
Led on indicates that the solenoid valve
S.V. ON
controlled by the units is open. In normal
(1)
standby state, this LED should not be on.
Led on indicates that the solenoid valve
controlled by the unit is open due to
BY-PASS
manual operation by the supervisor. In
(2)
normal operating state, this LED must
be off.
ONLINE
Led on indicates that the device is
(3)
correctly connected to the installation.
E.O.L
Led on indicates that the terminating
(4)
resistor is activated.