3" (7.6cm)
or Larger
HOT
4. Connect Supply Hoses
NOTE
If your installation requires that you coil the supply hoses to
:
obtain a good connection, maintain an inside coil diameter of at least
3" (7.6cm).
- Very carefully position the hot and cold supplies so they do not
interfere with the spray hose and the weight.
- Connect the supply hoses to the supply stops. (Left is hot - right is
cold.)
- Tighten all connections.
5. Flush Faucet
- Pull the sprayhead out to partially expose the hose. Remove the
sprayhead and screen gasket.
- Position the hose in the sink. Tie or tape the hose to the sink to
prevent it from sliding back into the faucet.
- Turn on the hot and cold water supplies. Turn the faucet handle to
the cold side and lift to the ON" position.
- Run water through the faucet for about one minute to remove any
debris. Without turning the water off, rotate the faucet to the hot side
and flush for another minute.
- Reinstall the screen gasket and sprayhead. Turn the water on and
check for leaks.