Please Observe The Following; Cleaning And Care Of The Equipment; Cleaning; Descaling - NUK Vapo Rapid Instrucciones De Operación

Ocultar thumbs Ver también para Vapo Rapid:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
Vapo Rapid 09-2014 Seite 17 Mittwoch, 24. September 2014 6:05 18
switch 8 to "OFF". This stops sterilisation
being started accidentally.
4.3 Please observe the
following:
• The sterilisation process lasts approx.
8 minutes using 70 ml of water.
• Sterilisation is only guaranteed if the
process is not interrupted and the time is
not reduced.

5. Cleaning and care of the equipment

5.1 Cleaning

To prevent the risk of an
Warning!
electric shock, injury or damage:
– Always detach the plug before
cleaning the appliance.
– Only ever clean the appliance
once it has cooled down.
– Never immerse base 6 in water.
Beware! Under no circumstances use
scouring agents or corrosive or abrasive
cleaning materials, as these could damage
the appliance.
1. Remove lid 1, accessory basket 3, bottle
holder 4 as well as steam receptacle 5
from base 6.
2. Wipe base 6
with a damp
each use.
3. Clean lid 1, accessory basket 3, bottle
holder 4 as well as steam receptacle 5
either with washing-up liquid or in the
dishwasher.

6. Faults and their rectification

Fault
Sterilisation takes too long
The appliance does not
switch on, Indicator light 9
does not light up
• If
sterilisation,
germfree for up to 24 hours.
• You should use only normal tap water
without added chemicals.
• Ensure that the equipment is descaled
on a regular basis in accordance with
"5.2 Descaling" to ensure the steriliser
continues to function correctly.

5.2 Descaling

After
hardness of your tapwater), the boiling
process will cause limescale to form in the
evaporator tray of the steam steriliser. You
should remove this regularly to ensure the
steriliser functions correctly as limescale
can greatly reduce its performance during
sterilisation.
Beware!
available descalers, pure acetic acid or
vinegar essence.
1. To get rid of limescale, we recommend
pouring 35 ml of white vinegar and 35 ml
of boiling water into the steriliser and
leaving it to take effect for 30 min.
cloth after
N.B.: longer periods will not improve
descaling
appliance in the long term.
2. After this time, empty the steriliser, rinse
out twice with clean water and wipe dry.
Cause
Too much water in
receptacle
Base is heavily scaled
No power supply
17
the
lid
remains
closed
the
contents
some
time
(depending
Do
not
use
commercially-
but
may
damage
Rectification measure
Measure exactly 70 ml for optimum
sterilisation.
Descale base (see "5.2 Descaling" on
page 17)
Push plug in correctly
Switch on the device
by sliding "ON/
OFF" switch 8 to "ON".
after
remain
on
the
the

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

10.251.01210.749.054

Tabla de contenido