Installation Of Additional Components - Wilo -EMU RZP 20 Instrucciones De Instalación Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5.3
Flexible installation with lowering
device
Fig. 4: Flexible installation
5.4
Installation of additional compo-
nents
Installation and operating instructions Wilo-EMU RZP 20-1 ... 80-2
Installation
The installation follows the installation of the submersible mixer. Note the following points:
▪ The recirculation pump cannot be operated at different heights.
▪ After lowering, the flow ring must be in complete contact with the discharge pipe.
▪ Guidance along the guide pipe is not by a frame at the motor. Guidance is by the flow ring.
▪ When lowering, tilt the recirculation pump approx. 5° downwards. Adjust the attachment
point accordingly.
▪ NOTICE! For types RZP 50-3..., RZP 60-3... and RZP 80-2..., additional components must
be fitted to the discharge pipe. Refer to the following chapter!
Install the following components depending on the type:
▪ Compression element
Ensures better contact between the flow ring and the discharge pipe and easier removal of
the recirculation pump.
▪ Claw
Ensures better contact between the flow ring and the discharge pipe.
Allocation of component to pump
Type
Compression element
Claw
-
-
-
-
-
-
-
-
-
en-US
-
-
-