Technical Data; Specified Conditions Of Use - Gude KLS 18-0 Traducción Del Manual Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34

Technical Data

Compressor and air pump set
Art. No
Supply voltage
Compressor
Real quantity delivered 0 bar
max. Pressure
Dimensions L x W x H
Weight without battery
Air pump
Air delivery rate
Dimensions L x W x H
Weight without battery
Noise details
Sound pressure level L
pA
Measured sound power level L
Guaranteed sound power level L
Measured according to EN ISO 12100:2010; Uncertainty K =1,5 dB (A)
Wear ear protectors!
Vibration details
Vibration total values (triaxial vector sum) determined according to EN 60335
Vibration emission value a
Uncertainty K = 1,5 m/s
2
Damage to health arising from vibrations to hand and arms if the device is used for a long time or if the device is
not guided and evaluated properly.
Vibration damping systems are no guaranteed protection against white finger disease or carpal tunnel syndrome.
Therefore, it is necessary to carefully check the state of your fingers and wrist if you have regularly used the appli-
ance for a long time. If any symptom of the diseases above appears, seek medical advice immediately. To reduce
the white finger disease risk, keep your hands warm and take regular breaks during your work.
Read and understand the operating
instructions before using the appliance.
Familiarise with the control elements
and how to use the appliance properly. Abide by all the
safety measures stated in the service manual. Act
responsibly toward third parties.
The operator is responsible for accidents or risks to third
parties.
Persons over 16 years of age can only work on the
appliance. An exception includes youngsters trained
in order to reach knowledge under supervision
of the trainer during occupational education.
In case of any doubts about connection and operation
refer please to our customer center
This appliance has not been designed to be used by per-
sons (including children) with reduced physical, sensory
or mental capabilities or with a lack of knowledge or
experience.
Children must be supervised in order not to play with
the machine.
WA
WA
h

Specified Conditions of Use

The compressor may only be used to generate com-
pressed air for household and hobby use. – Respecting
technical data and safety precautions.
The compressed air produced by the unit
cannot be used in the pharmaceutical, food or
hospital sectors and must not be used to fill
diving gas cylinders.
The appliance must be used in suitable rooms
(well ventilated, with a room temperature
between +5° and +40°C), never in the presence of
dust, acids, vapours, explosive or flammable
gases.
Not observing general regulations in force and instruc-
tions from this manual does not make the manufacturer
liable for damages.
ENGLISH
KN 18-0
58427
18 V
30 l/min
7 bar
235 x 163 x 68 mm
0,7 kg
45 m³/h
245 x 123 x 85 mm
0,9 kg
80,5 dB (A)
91,5 dB (A)
92,0 dB (A)
1,527 m/s
2
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

58427

Tabla de contenido