Use In Explosive Atmospheres; Assembly - SATA 500 Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 85
Operating Instructions SATA filter 500
EN
6.2. Filter Specific Safety Instructions
• Local safety, accident prevention, work and environment protection
regulations are mandatory!
• Use, cleaning and maintenance by skilled personnel only!
• Never use the filter when it is damaged or when components are
missing!
• Check and, if necessary, repair the filter on a regular basis!
• Put filter out of operation immediately when it is damaged!
• Never carry out unauthorised or technical modifications on the filter!
• Use original SATA spare parts and accessories only!

6.3. Use in explosive atmospheres

The filter is approved for use in potentially explosive atmospheres of ex-
zone 1 and 2. Heed the product ID.
7.

Assembly

7.1. SATA filter 500
• Drill holes in wall as illustrated for SATA filter 584 [2-1], SATA filter 544
[2-2] or SATA filter 524 [2-3]
• Remove filter housings [1-9] [1-11] and [1-12]
• Firmly fasten filter to wall in a horizontal position, using enclosed screws
• Connect air inlet G ½" (internal thread) to compressed air line with
detachable bolted connection
• Mount the filter housings on [1-9], [1-11] and [1-12] on the filters
(Caution! Filter housings are only correctly fitted after an audible
"click"!) and then attach the SATA filter timer [1-5] and press to activate
• Slide condensate drain hose [1-14] over the drain valve [1-10]; put
the end of the hose in a suitable collecting tank (not included in deliv-
ery).
76
Warning! Attention!

Publicidad

Tabla de contenido
loading

Tabla de contenido