Spraying
The pressure sprayer must be de-pressurized To
pump, loosen the pump handle by turning out of
the stop position.
Fig. 5: Pump the unit until the operating pressure
is reached in the container. Excessive pressure
escapes automatically through the safety valve.
Take the spray tube in your hand and start the
spray process by pressing the shut-off valve.
Releasing the shut-off valve stops the spray
process.
Fig. 6: Nozzle adjustment
a) Closed
 hollow cone
Delivery rates 2 bar: 0.45 l/min
_________________________________
b) Open max. 360°
Delivery rates 2 bar: 0.70 l/min
The spray tube can be rotated in the shut-off valve
– after loosening the threaded collar – this is
useful for spraying under leaves.
- ENGLISH –
 coarse and narrow

Cleaning, care and storage

After each use, release pressure, always keeping
the sprayer in vertical position. Empty the
container, carefully clean, and rinse well with clean
water. Do not empty residual quantities of spray
liquid into watercourses; rather dispose of them via
communal disposal systems.
For cleaning nozzle, spray tube, and shut-off valve,
operate the sprayer using clean water (add
dishwashing detergent if required).
Fig. 7: Occasionally clean the filter and spray
nozzle with water and a soft brush. Never use your
mouth to blow through the spray nozzle!
Never use aggressive, acidcontaining, solvent-
containing cleaning substances (gasoline for
example).
Always empty the sprayer completely and store it
in a location that is dry, frost-free, and protected
from direct sunlight.

Technical data

Maximum fill volume
Tank capacity
Permissable operating pressure
Permissable operating temperature
Mesh width of filter screen
in spray tubing
Max. Delivery rates 2 bar:
Weight empty
__________________________________________
In the best interest of continued technological
progress we reserve the right to change the design
and configuration of any product without prior
notice.
For that reason, no claims can be accepted with
reference to text and illustrations in this manual.
11.0 l
13.5 l
2 bar
0ºC - 40ºC
0.8 mm
0.70 l/min
3.370 kg