TROUBLESHOOTING CHECKLIST

PROBLEM
Pump runs, but does
not deliver water.
Pump won't run.
Pump starts too frequently.
Pump does not shut off
automatically.
Pump blows fuses, trips
breakers, or overloads.
LIMITED WARRANTY
WATER ACE warrants to the original consumer purchaser ("Purchaser") of its products that they are free from defects in material or workmanship.
If within twelve (2) months from the date of the original consumer purchase any such product shall prove to be defective, it shall be repaired or replaced at WATER
ACE's option, subject to the terms and conditions set forth below. Your original receipt of purchase is required to determine warranty eligibility.
Exceptions to the Twelve (12) Month Warranty
Product
R06, R07 Non-Submersible Utility
RES Submersible Utility, R33SP Submersible Sump Pump
R50SP Submersible Sump Pump, R3S Submersible Sump Pump, R7PBS Pressure Booster Pump
R5V Submersible Sump Pump
R50VLT, R75VLT Sump/Effluent Pumps, R5PILT Pedestal Sump Pump, R7W Submersible Sewage Pump
General Terms and Conditions
Purchaser must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty shall not apply to acts of God, nor shall
it apply to products which, in the sole judgement of WATER ACE, have been subject to negligence, abuse, accident, misapplication, tampering, alteration; nor due to
improper installation, operation, maintenance or storage; nor to other than normal application, use or service, including but not limited to, operational failures caused
by corrosion, rust or other foreign materials in the system, or operation at pressures in excess of recommended maximums.
Requests for service under this warranty shall be made by returning the defective product to the Retail outlet or to WATER ACE as soon as possible after the discovery of
any alleged defect. WATER ACE will subsequently take corrective action as promptly as reasonably possible. No requests for service under this warranty will be accepted if
received more than thirty (30) days after the term of the warranty.
This warranty sets forth WATER ACE's sole obligation and purchaser's exclusive remedy for defective products.
WATER ACE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICABLE EXPRESS WARRANTIES
PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above
limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
Water Ace Pump Co. | 0 Myers Parkway | Ashland, Ohio 44805-969
23833A09
(CAUTION: SHUT OFF POWER TO PUMP)
• Check valve is stuck. Shake pipe or raise and lower the unit. If pump still does not operate properly, remove pump from
well and clear obstruction from check valve.
• Low voltage to pump. Have voltage checked by an electrician.
• Clogged intake. Clean screen or slots in inlet bowl.
• Impellers and diffuser worn or packed with sand or debris. Clean or replace.
• Low well water level. Lower pump deeper into the well or install
• Low restrictor.
• Well too deep for pump. See charts on page  for appropriate operating depths.
• Leaks. Check all connections for airtightness.
• Check for blown fuse or tripped circuit breaker and for broken or open leads in piping.
• Pressure switch malfunction. Replace.
• Control panel malfunction (3-wire pumps only). Have an electrician check it.
• Pressure switch out of adjustment. Follow instructions on inside of switch cover.
• Check valve stuck open or seated improperly. Clean or replace.
• Pressure tank is waterlogged. Bladder tanks: release air from tank air charge valve. If water bubbles or spits from valve,
the bladder has a hole in it. Galvanized tanks: check for a defective air-volume control.
• Leak in system.
• Pressure switch out of adjustment. Follow instructions on inside of switch cover.
• Defective pressure switch. Replace.
• Worn pump.
• Low well water level. Lower pump deeper into the well or install flow restrictor.
• Well too deep for pump. See charts on page  for appropriate operating depths.
• Fuses or breakers are too small. See fuse chart on page 0.
• Wire size is too small. See wire size chart on page 0.
• Motor or cable is grounded. Have an electrician check with an ohmmeter.
• Voltage too high or too low. Have it checked by an electrician.
• Incorrect control box (3-wire pumps only). Compare nameplate rating on box to pump HP.
-800-942-3343 (U.S.A. only)
POSSIBLE CAUSES
2
Warranty Period
90 Days
2 Years
3 Years
5 Years
Lifetime
Bag #23834A004