Lowering The Pump - Water Ace R200A Manual De Instalación

Ocultar thumbs Ver también para R200A:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installing a submersible well pump, continued.
Process B: Steps 1 through 5, At The Well, Continued.
Well Seal
STEP
4
The following steps illustrate the process of a well
seal installation. Thread 1-1/4" galvanized steel
female adapter onto 8" galvanized steel nipple and
thread 1-1/4" male barbed adapter into galvanized
steel female adapter
STEP
5
Clamp the other end of polytubing onto barbed
adapter with two clamps. FOLLOW STEPS 1–5 OF
PROCESS A, THE PUMP. Slide well seal over 8"
galvanized steel nipple. Slide wires through one of
the smaller holes in the well seal, leaving slack for
polytube stretch. Slide safety rope through other
hole in well seal and tie rope around discharge
(see figure O)
pipe
steel elbow onto 8" galvanized steel nipple. Thread
1-1/4" to 1" male PVC reducer into elbow
figure P)
. With someone's help, carefully slide
pump assembly down well. Turn well seal nuts
clockwise until well seal firmly clamps 8" galvanized
steel nipple.

Lowering the pump

Process C: Step 1 (only) Lowering The Pump
With someone's help, carefully lower pump assembly
STEP
into well. Firmly grasp assembly and safety rope
1
tied to well cap to prevent assembly from falling
into the well.
Pitless Adapter: Slide pitless pipe junction into
adapter slot.
Well Seal: When pump reaches correct level, mount
well seal on top of well casing and tighten bolts to
clamp pipe securely.
After Process C: Step 1 Lowering The Pump has
been completed, please proceed to Process D:
Steps 1 through 4, At The House.
CONSUMER HOT-LINE:
1-800-942-3343
Monday–Friday 7 AM to 5 PM EST
www.waterace.com
23833A09
(see figure N)
.
N
8" NIPPLE
FEMALE
ADAPTER
BARBED
ADAPTER
.
Thread 1-1/4" galvanized
(USA only)
TO PRESSURE
SWITCH (2-WIRE)
TO CONTROL BOX
(3-WIRE)
O
SLACK FOR
POLYTUBE
(see
8
OPTIONAL
GATE VALVE
COMPLETE
WELL SEAL
INSTALLATION
A typical well seal
submersible well pump
installation
ELBOW
WIRES TO
POWER
SUPPLY
WELL
SEAL
STRETCH
SAFETY
ROPE
LOWERING THE PUMP
CHECK VALVE
EVERY 200 FT.
(60 METERS)
SAFETY
CABLE
10 FT. (3 METERS)
MINIMUM
5 FT. (1-1/2
METERS)
MINIMUM
P
REDUCER
TAPE CABLE
EVERY 10 FT.
(3 METERS)
DRAWDOWN
WATER LEVEL
BOTTOM
OF WELL
Bag #23834A004