GB T5 AUTO SHORT - 230V - 50HZ - 6 Nm 17 rpm.
S.A.S. au capital de 5 000 000 € - Z.I. Les Giranaux - BP71 - 70103 Arc-Les-Gray CEDEX - RCS GRAY B 425 650 090 - SIRET 425 650 090 00011 - n° T.V.A CEE FR 87 425 650 090
Installation
1
- The motor torque must be selected according to the shutter's characteristics. Do not oversize the operator.
- The use of automatic locking devices (VAR, VAS or EASYLINK) and stops on the fi nal slat is mandatory in order to ensure proper
working of the motor.
- To receive information regarding the compatibility of the motor and the roller shutter or/and accessories, contact the roller shutter
manufacturer or SIMU.
- Noise level : LpA ≤ 70 dB (A)
- Drilling of the tube:
55
22,8
48*
4
* 35 Nm max.
Assembly :
9910013
9910014
25 N.m max.
2
Wiring
Blue
N
Brown
L
Black
PE
Green/yellow
- 3 operators (max.) can be wired in parallel on one switch.
- The wiring has to be realized by trained people.
- The motor does not allow connection with an emergency power supply such as regulated power supply or power generating unit.
- The connector has to be assembled without damaging the contacts. The continuity of the earth connection must be ensured.
- Please do contact SIMU when using KNX / EIB electronic switching control devices.
Power up of the operator
3
After the fi rst two consecutive opening and closing of the shutter :
- The motor memorizes automatically the end limit ( up and down) positions.
- The "stop on obstacle" function is activated.
>>
- It is advised to carry out these two opening / closing cycles as soon as the product is installed.
- For any further information, please consult the SIMU technical leafl et 5056893.
Cancelling the automatic settings
4
- In the case of a new installation with this operator, it is advised to reset the motor according to the following procedure:
>>
>>
1 s
1 s
- Press 3 consecutive times, for 1s each time, on the UP key. The motor runs briefl y at each press.
- Press 3 consecutive times on the DOWN key. The fi rst two press for 1s (the motor runs briefl y at each press) and the third press for 2s. The motor runs twice in the same
direction.
364
387
1
5
2
2
1
2
3
1
2
>>
>>
1 s
351
4 x Ø5 / 90°
47
min.
Ø4,8 x 10
STEEL
4
Ø5 x 10
3
1
35 N.m max.
T5 AUTO SHORT
>>
1 s
5057712C
Read carefully these instructions
24
45
120
0.2m
3
1
OK
>>
>>
>>
>>
1 s
before any use.
V.A.R
V.A.S
EASYLINK
MANDATORY
N
Blue
L1
Brown
L2
Black
PE
Green/yellow
3.00m
2
1
1
2
>>
3
>>
>>
2 s
1/1

Publicidad

loading