Installer Mode - EQUATION TH30DP4 Manual De Instrucciones

Termostato de ambiente digital programable, con cable para caldera de contacto seco., instalación de pared
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10

Installer Mode

The thermostat is factory set to control a gas boiler.
Installer Mode allows you to modify these factory settings respecting the below values.
Applications
Gas boiler (<30 kW)
Oil boiler - Heat pump
Pellet stove
1 - Press the OFF Key.
2 - Maintain pressure simultaneously on
PROGRAM
and
fi rst parameter of level 1 of the installer parameters (from
parameter 1 to parameter 19).
3 - Press
or
to change the factory setting. The
display is fl ashing to indicate that this change has been
taken into account.
4 - Press the green key
stops fl ashing.
5 - Press
to go to the next parameter.
6 - Press PROGRAM
parameters (parameter 1 to parameter 5).
7 - Press AUTO, MAN or OFF to exit installer mode.
Parameter
1:CL
AM-PM / 24hr Display
2:rP
Reset Time/ Temp Programs
6:UL
Upper temperature limit
7:LL
Lower temperature limit
12:tO
Temperature off set
13:Pb
Proportional Band Width
19:FS
Reset Parameters to Factory Defaults
1:Ot
Minimum boiler ON time
2:Cr
Cycle Rate
5:PE
Pump Exercise
Type of Control
Electrical protection
Type of Batteries
Temperature range
Action
Rated current
Environment
Regulation class
(according 811/2013)
Energy effi ciency gain (contribution to seasonal space heating energy effi ciency)
Class of Software
Supplier
Cycles / hour
6
3
and
. T he screen then displays the
to confi rm the change. The display
. to go to level 2 of the installer
Description
Technical data
Independently mounted control for Surface mounting
IP30
No protection against water ingress
CLASS II
Product that does not incorporate protective earthing provision,
but a double insulation as provision against electric shock
2 batteries AA (LR06 ) 1,5 V (not supplied)
5-35°C
Micro-interrupt, Type 1 .C
Rated voltage : 24-230V~, 50-60Hz - Max rated current for Resistive load : 5A
Max rated current for Inductive load : 2A
Pollution degree = 2 (standard household conditions without conductive dust)
Class IV
Class A
ADEO Services - 135 Rue Sadi Carnot, CS 00001, 59790 - RONCHIN - FRANCE
mini ON time
1 min
4 min
Values range
12, 24 h
0, 1
21 ... 35°C
5 ... 21°C
-3 ... +3°C
1.5 ... 3°C
0, 1
1 ... 5 min
3, 6, 9, 12
0,1
Rated impulse voltage
Overvoltage Category according IEC/EN 60730-1
Settings to change
No change
Parameter 1:Ot on 4
Parameter 2:Cr on 3
Default value
24h
1
35°C
5°C
0
1.5°C
1
1min
6
0
2500 V
2%
II
FR
ES
PT
IT
EL
PL
UA
RO
EN
49

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

82823692

Tabla de contenido