Drain Test
Feed Water
Flexible
Drain Hose
Panel Installation
Good Installation
Air intake grille installation
•
Before installing the air intake grille, be sure to fix the
ionizer filter to the air filter.
•
Install the air intake grille together with the air filter to the
front panel.
•
The grille can be fit in any direction, when selecting
direction, the ceiling design and grille operability should
be considered.
•
If the unit comes with ionizer filter (optional item), make
sure to fix the ionizer filter to the air filter before installing
the air intake grille.
•
Fix the ionizer filter to the air filter with the black side on
top and white side at bottom.
•
Carefully clip on the ionizer filter frame.
Main Drain Pipe
OPEN
Screw
Indoor unit
cool
air
ceiling board
Panel
•
Connect the main drain pipe to the flexible drain hose.
•
Feed water from flexible drain hose to check the piping
for leakage.
•
When the test is completed, connect the flexible drain hose
to the drain connector on the indoor unit.
NOTE
This indoor unit uses a drain pump for condensed water
drainage. Install the unit horizontally to prevent water
leakage or condensation around the air outlet.
•
Be sure to remove the installation template before install-
ing the front panel.
•
Open the air intake grille by pulling back the catchers and
removing it together with filter from panel.
•
Install the front frame panel onto the indoor unit by 4
screws and tighten it completely to prevent cool air leak-
age.
•
Connect the LED wire and air swing wire to the indoor
unit.
LED Wire
From
Front
Panel
Air Swing Wire
NOTE
Install the front frame panel firmly to prevent cool air
leakage which will cause condensation and water dripping.
air leak
Bad Installation
Frame
Ionizer
Filter
1-5
cool
air
air leak
ceiling board
Panel
From
Control
Box