Place the TRANSFORM unit in the shade if possible and in a cool place in order to increase efficiency and
to avoid overheating. At an ambient temperature of over 35°C, the TRANSFORM unit may deactivate. If
this occurs continuously, we recommend you temporarily use the INDOOR OPERATION of the
TRANSFORM unit. We recommend that a drainage hose for condensation water be connected.
Set the function to „COOLING". The settable temperature range is between 17°C and 30°C. This can be
set using the temperature control.
The air with high oxygen content cooled by the TRANSFORM unit is led into the room via the air hose.
This can be executed e.g. via a tilted window, a door or wall aperture. Make sure that no warm outside air
can enter the room. We recommend that a drainage hose for condensation water be connected. For
effective cooling, we recommend our selection of various accessories which reduce or prevent entry of
warm air into the room, or via the remote control.
Using the „Comfort Control- S Kit" you can also control the TRANSFORM unit from inside using the
remote control.
Note: After switching on, or over, the ventilator operates, but the compressor only starts after the control
lamp has flashed for 3 minutes. Cooling effect may require a further 10 minutes. Further information is
available under the part „Troubleshooting".
HEATING
 On cold days it is recommendable to start the TRANSFORM unit early in order to get a warm room.
 For the heating function and to improve the heating effect and avoid lower temperatures (lower than
17°C) we recommend you remove the rubber plug from the condensation water outlet and allow the
condensation water to leak out of the TRANSFORM unit using the drainage hose. However, the
drainage hose does not have to be connected in the heating mode. Please make sure that the
condensation water outlet is closed with the rubber cap during operation. In such a case, proceed
analogously to the emptying of the water tank in the cooling function.
 The heating function of the TRANSFORM unit must not be operated at a room temperature of more
than 23°C or less than 7°C. The TRANSFORM unit can also be operated with heating function, if the
outside temperature is lower than 7°C. However, you must then ensure that the TRANSFORM unit is
operated inside and the room temperature is at least 7°C.
Caution: In the heating mode, separate setting of the ventilator is not provided, since the highest
ventilation level is already preset to avoid overheating of the unit.
HEATING IN INDOOR OPERATION
The TRANSFORM unit is in the room to be heated.
Connect the air hose and the air outlet grid to the TRANSFORM unit as displayed in the illustration; the air
hose connection piece and air outlet grid need to be exchanged.