CONVERSION
WARNING
Fire, Injury, Death Hazard
Before beginning the conversion, you must turn OFF the gas
supply valve at the manual shutoff and disconnect the
equipment from the supply line.
Remove the orifice from each of the main burners
1. Lift off the complete griddle plate assembly to expose the main
burners, burner control valves, and the pilot burners.
2. Use an 8mm wrench to loosen and remove the nut fastening the
main burner to the frame.
3. Carefully remove the entire burner from the griddle.
4. The brass orifice, located on the end of the burner control valve, will
now be exposed. Use a 13mm wrench to remove the orifice.
Install the new orifice on each of the main burners
NOTICE: Derate at Altitudes Above 2000 ft (610m)
Ratings of gas utilization equipment are based upon
operation at sea level and shall not be changed for
operation at elevations up to 2000 ft (600m).
For operation at elevations above 2000 ft (600 m),
equipment ratings shall be reduced, at the rate of 4 percent
for each 1000 ft (300 m) above sea level, when calculating
how to select appropriately-sized orifices.
1. Apply a small amount of jointing paste to the thread on the end of
the control valve.
2. Install and tighten the new orifice.
3. Replace the main burner by sliding the open end over the new orifice
and then passing the stud through the slot at the rear of the burner.
4. Secure the main burner to the frame by reinstalling the nut and
tightening it with the 8mm wrench.
Change the pilot burner jets
1. Loosen and carefully remove the gas supply line from the pilot
burner assembly.
2. Remove the natural gas pilot jet from within the burner body.
3. Install LPG jet supplied in the kit.
®
2
Cayenne
Heavy-Duty Thermostatic Griddles – Conversion to LP Gas Installation Instructions
Adjust the gas regulator
Follow the steps below to adjust the gas regulator to operate at 10" WC
for use with LP gas.
1. Use a 22mm wrench to remove the conversion cap from the top of
the regulator.
Conversion cap and regulator pin
Gasket
Regulator
2. Remove the regulator pin, invert, and reinsert.
Natural gas
3. Replace the conversion cap, taking care that the regulator pin and
the gasket are both properly seated.
L.P.