Vollrath Cayenne FTT2024 Instrucciones De Instalación página 3

Ocultar thumbs Ver también para Cayenne FTT2024:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TEST THE EQUIPMENT
Check the pressure of the incoming gas line
Before supplying gas t the regulator, check the pressure of the
incoming gas line.
The regulator can withstand a maximum pressure of 14" WC (1/2 PSI).
If the line pressure is beyond this limit, a step-down regulator will be
required. The arrow on the regulator body shows gas flow direction and
should point toward the appliance.
Check for gas leaks
NOTICE: Matches, candle flame, or any other potential source of
ignition shall not be used for this purpose.
1. Turn the knob for the main burner(s) to the OFF position.
2. Connect the equipment to the gas supply.
3. Apply soapy water to each connection.
4. Turn ON the main supply valve.
5. Look for bubbles at the connections.
6. Adjust the connections as needed.
Light the pilot light burners
NOTICE: To light the pilot burner, you will need a flame source with
an extension which is at least 8" (20.3 cm) long. Hold the
flame source through the opening in the front panel near
the red button for the pilot light you are lighting.
1. Turn OFF the main gas valve to griddle.
2. Turn OFF all of the burner control valves.
3. Wait 5 minutes to allow any gas to dissipate.
4. Turn ON the main gas valve.
5. For each main burner and pilot burner, confirm that thermocouple
(currently at room temperature) is preventing the flow of gas. If the
thermocouple is defective, replace it before proceeding to Step 6.
6. Light the pilot burner while pressing the red button on the flame
failure protection device. Hold the button for at least 10 seconds to
allow the pilot flame to engage the thermocouple.
Test the main burners
After lighting all of the pilot burners, ensure that each main burner
functions correctly.
Reassemble the equipment
Allow the burners and surrounding surfaces to cool before
reassembling the equipment.
®
Cayenne
Heavy-Duty Thermostatic Griddles – Conversion to LP Gas Installation Instructions
AFFIX THE LABELS
1. Affix the Rating Plate, supplied in the kit, adjacent to the original on
the rear of the griddle.
The V ollrath Company, LLC
Sheboygan,WIUSA
1-888-882-6845
Griddle, Gas, Flat Top, HD, Thermostatic, 24"
Item: 924GGT
Converted for use with LP (propane) Gas
Model: FTT2024
Orifice Size: #51 Drill
Conversion Kit: XFTT2001LP
Conforms to ANSI
Conforms to
STD Z83.11-2016
NSF/ANSI STD 4
Certified to CSA
STD 1.8-2016
3095654
3095654
Intended for other than houshold use - Non destine a l'usage domestique
2. Fill in the details required on the Installation Plate, supplied in the kit,
and affix to the rear of the griddle.
CONVERSION BY QUALIFIED SERVICE AGENCY
THIS APPLIANCE WAS CONVERTED ON:
day
month
to LPG gas with KIT #:
by: C ompany
Address:
Which accepts the responsibility that this conversion has been properly made
3. Affix the Warning Label, supplied in the kit, near the regulator.
LPG GPL
FOR LP GAS WHEN EQUIPPED WITH NO. 51 DRILL SIZE ORIFICE
POUR LP GAZ LORSQU' ÉQUIPÉ 'AVEC UNE OUVERTURE
DE TAILLE DE MÈCHE NO. 51
MAN.PRESS.
INCH W.C.
10.0
PRESS. MAN.
TOTAL INPUT
60,000
TOTAL D'ENTRÉE
BTU/HR
BTU/H
FOR USE IN NON COMBUSTIBLE LOCATIONS ONLY
DOIT ETRE UTILISE SEULEMENT DAS DES LOCAUX NON INFLAMMABLES
FOR YOUR SAFETY REFER TO INSTALLATION INSTRUCTIONS FOR CONVERSION PROCEDURES
®
Input: 30 000 BTU
Manifold Pressure : 10" WC
Max. Pressure : 14" WC
Made in China
Fabrique aux La China
Hecho en China
year
CLEARANCES
ESPACES LIBRES
BACK
6"
ARRIERE
RT SIDE
6"
COTE DROIT
LT SIDE
6"
COTE GAUCHE