Make sure the batteries are charged.
Low or dead batteries decrease the efficiency of the pump, which then cannot provide
enough pressure in the preset time interval.
For this reason, ERR will appear. Replace the batteries.

MEMORY FUNCTION

This unit has the capacity to store up to 60 measurements in each memory zone (2 memory zones).
After each measurement, the following values will be stored automatically: diastolic, systolic,
pulse rate, date and time, memory number, segments for classifying blood pressure values (see
"CLASSIFICATION OF BLOOD PRESSURE VALUES" section) and the possible presence of irregular
heartbeat (arrhythmias) (
) when the heart symbol is shown.
To recall the stored measurements in the last memory zone selected, you must press the "M" key.
On the display will appear ( ) or ( ).
To scroll through the data in memory press the "M" key again (each press of the key scrolls
through the data) and there will appear in succession:
• the word "AVG" which indicates the average of the last 3 measurements
• in the lower right of the display the memory number
• the stored values
The number "60" is the oldest measurement, while the number "1" indicates the most recent value.
Switch off the appliance by pressing the "O/I" button.
After more than 60 measurements, the oldest data are automatically cancelled. .
To recall the memory area other than the last one selected before the last measurement, with the
unit off it is necessary to hold the "O/I" button for 3 seconds.
On the display the last memory zone selected will flash ( or ). Press the "M" key to select one
of the two memory zones and confirm the selection by pressing the "O/I" button. At this point,
turn off the unit by pressing and holding the "O/I" button for about 3 seconds.
DELETION OF STORED DATA
Deleting all data stored in a memory zone.
When the appliance is turned off recall your memory zone by pressing the "O/I" button for 3
seconds and then the "M" key to select the memory zone and confirm by pressing the "O/I" button.
Then switch off the unit, holding down the "O/I" button for about 3 seconds.
WRIST BLOOD PRESSURE MONITOR
36
Instructions and guarantee
At this point, press the "M" key and then the "O/I" button for about 3 seconds, the unit will emit
a short beep and the display will show "---". Now all the data in the previously selected memory
zone will have been deleted.
INDICATORS
The following symbols may appear on the display:
: MEMORY AREA No.1: It appears when the measurement is stored
in the first memory area.
: MEMORY AREA No.2: It appears when the measurement is stored in
the second memory area.
Err
: no measurement could be taken as the arm moved, incorrect position, other ...see
section entitled "CORRECT MEASURING METHOD".
: batteries finished. Replace batteries.
: pulse frequency symbol.
: indicator of irregular pulse
: reference segments for the classification of the blood pressure values
"AVG"
: indicates the average of the last 3 measurements

CARE AND MAINTENANCE

• This unit contains precision components.
Hence, care must be exercised to avoid exposing the unit to extreme changes in temperatures,
humidity, knocks, dust and direct sunlight. Do not drop or hit the unit.
• Clean the unit using a soft, dry cloth only.
Do not use any chemical or abrasive products to clean the monitor.