Setting The Detector - United Technologies interlogix VE700AM Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
24
26
EN: Installation Manual
Introduction
The VE735AM and VE736AM are PIR-AM motion sensors.
They have a patented verified PIR technology, with multi-
channel anti-masking.
Installation guidelines
The technology in this detector resists false alarm hazards.
Nevertheless avoid potential causes of instability, such as:
Direct sunlight on the detector
Heat sources within a field of view
Strong draughts onto the detector
Large animals in a field of view
Objects within 50 cm (20 in.) of the anti-masking (AM)
detector
Obscuring the detector's field of view with large objects,
such as furniture
Installing two detectors facing each other and less than
50 cm apart
Install the detector so that the expected movement of an
intruder will be across the fields of view (see example in
Figure 21, item 1). This is the direction best detected by PIR
detectors.
6 / 60
25
Mounting the detector
1.
Lift off the custom insert and remove the enclosed screw
(Figure 1).
2.
Using a screwdriver, carefully prise open the detector
(Figure 2).
SB01
3.
Remove the interior part (Figure 3).
4.
Fix the base to the wall between 1.8 m and 3.0 m (5.9 to
9.8 ft.) from the floor. For flat-mounting use a minimum of
two screws (DIN 7998), at least one in position A and one
in position B. For corner-mounting use screws in positions
C or D (see Figures 4 and 5).
Note:
pry-off positions are shown in the warning box.
5.
Wire the detector. See Figures 7 and 8.
Note:
Electrical Code, NFPA 70 and CSA C22.1, Canadian
Electrical Code, Part I, Safety Standard for Electrical
Installations.
Figure 16 shows a single detector wiring, Figure 17 —
multiple devices connection.
6.
Select the desired jumper and DIP switch settings (see
"Setting the detector" below).
7.
Replace the interior part (Figure 9).
Align the detector. See "Aligning the beam and walk
8.
testing the detector" on page 8.
9.
Remove the blinders and add the stickers, if required. See
"Selecting the coverage pattern" on page 9 and "Blocking
the curtains" on page 9.
10. Insert the insect-protection caps (Figure 10, item 1).
11. Close the cover (item 2).
12. Insert the screw (if required) and replace the custom insert
(item 3).

Setting the detector

The detector must be restarted (repowered) after changing the
settings or detection pattern.
CP
ST400
Not all screw positions have pry-off tamper. Non
All wiring must be provided according to National
P/N 149973999-3 (ML) • REV G • ISS 20DEC18

Publicidad

Tabla de contenido
loading

Productos relacionados para United Technologies interlogix VE700AM Serie

Este manual también es adecuado para:

Interlogix ve735amInterlogix ve736am

Tabla de contenido