Troubleshooting - Midland ENERJUMPTRUCK Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
3
STARTING A VEHICLE
Make sure that Enerjump Truck is properly charged (the number of the indicator lights must be not less
than 3).
• Turn off all the accessories on the vehicle.
• Connect the red battery clamp of the jumper cable to the vehicle's positive (+) battery terminal and
connect the black battery clamp to the vehicle's negative (-) battery terminal. Warning: pay attention
to the polarity!
The product will automatically identify the 12V/24V auto voltage (Smart Jump Start System™)*.
• Turn the ignition key to start the vehicle.
• If the engine starts, disconnect the red and black clamps from the vehicle's battery terminal within 30
seconds.
• Leave the vehicle's engine running for a few minutes.
• If the vehicle does not start on the fi rst trial, wait for 1 minute before trying to start the vehicle again.
* If the product will NOT automatically identify the 12V/24V auto voltage please proceed as follows :
• Check the connection of the Enerjump Truck clamps to the battery of the vehicle.
• If the product doesn't recognize the auto voltage automatically, keep pressed the 12/24V Switch ac-
cordingly to the vehicle battery type.
NOTE: This procedure will disable the Smart Jump Start System™ (see point before).
• If still no Jump Start Reaction after the above steps, please check the vehicle to see if other problem
happens.
TROUBLE SHOOTING
PROBLEM
12V/24V indicators are blinking
12V/24V indicators are blinking
when connected to vehicle's
battery
10
1
2
4 5
12/24V
CAUSES
Self protection against short cir-
cuits
Self protection against polarity
inversion.
6
12/24V
CORRECTIVE ACTION
Unlock Enerjump Truck by pu-
shing the Switch Test for 5 se-
conds after the short circuit has
been removed.
Check if the Red and Black
clamps are connected in the
proper mode.

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido