Tabla Parámetros Para Exv - EUROKLIMAT EKE Serie Manual De Uso Y Mantenimiento

Tabla de contenido

Publicidad

PUESTA EN MARCHA Y PANEL DE MANDO
A056
S
A056 - Alarm relay configuration
A057
M
A057 - Delta temp. to activate free-cooling coil regulation
A058
M
A058 - Free-Cooling On-Off hysteresis
A059
M
A059 - Delta temp.(Water In - Source) for 100% FC capacity
A060
M
A060 - Free-cooling type (0=Air; 1=Air remote; 2=Water)
A061
S
A061 - Antifreeze type (0=Heater; 1=Pump; 2=Heater-Pump)
A062
S
A062 - Enable setpoint compensation function
A063
S
A063 - Enable free-cooling function
A064
M
A064 - User pump number
A065
M
A065 - Unit type (0=CH; 1=HP; 2=CH/HP)
5.5.4 Tabla parámetros para ExV
p
Param.
PW
Variable Description
Code
D
B000
S
B000 - ExV circuit 1 enable manual mode
B001
S
B001 - ExV circuit 1 manual mode
B002
S
B002 - ExV circuit 2 enable manual mode
B003
S
B003 - ExV circuit 2 manual mode
B004
S
B004 - ExV SH setpoint in cooling
B005
S
B005 - ExV proportional gain SH regulation in cooling
B006
S
B006 - ExV integral time SH regulation in cooling
B007
S
B007 - ExV derivative time SH regulation in cooling
B008
S
B008 - ExV SH setpoint in heating
B009
S
B009 - ExV proportional gain SH regulation in heating
B010
S
B010 - ExV integral time SH regulation in heating
B011
S
B011 - ExV derivative time SH regulation in heating
B012
S
B012 - ExV low SH threshold in cooling
B013
S
B013 - ExV integral time low SH in cooling
B014
S
B014 - ExV low SH threshold in heating
B015
S
B015 - ExV integral time low SH in heating
B016
S
B016 - ExV LOP regulation threshold in cooling
B017
S
B017 - ExV integral time LOP regulation in cooling
B018
S
B018 - ExV LOP regulation threshold in heating
B019
S
B019 - EEV integral time LOP regulation in heating
B020
S
B020 - ExV MOP regulation threshold in cooling
B021
S
B021 - ExV integral time MOP regulation in cooling
B022
S
B022 - ExV MOP regulation threshold in heating
B023
S
B023 - ExV integral time MOP regulation in heating
B024
S
B024 - ExV low SH alarm delay time
B025
S
B025 - ExV LOP alarm delay time
B026
S
B026 - ExV MOP alarm delay time
S
B027 - ExV high condensing temperature threshold
B027
B028
S
B028 - ExV high condensing temperature integral time
B029
S
B029 - ExV high condensing temperature alarm delay time
B030
S
B030 - ExV low suction temperature alarm threshold
B031
S
B031 - ExV low suction temperature alarm delay time
B032
S
B032 - Capacity ratio (EVAP / EEV) in cooling
B033
S
B033 - Capacity ratio (EVAP / EEV) in heating
B034
S
B034 - Pump down end temperature threshold
B035
S
B035 - Pump down maximum time duration
B036
S
B036 - Pump down type
B037
S
B037 - ExV regulation delay after power-on
B038
M
B038 - ExV minimum steps custom
B039
M
B039 - ExV maximum steps custom
B040
M
B040 - ExV full closing steps custom
B041
M
B041 - ExV move rate custom
B042
M
B042 - ExV emergency fast close rate custom
B043
M
B043 - ExV move current custom
B044
M
B044 - ExV hold current custom
B045
M
B045 - ExV duty cycle custom
B046
M
B046 - ExV opening valve position synchronization custom
B047
M
B047 - ExV closing valve position synchronization custom
B048
M
B048 - ExV power supply mode (0=24 Vac; 1=24 Vdc)
B049
M
B049 - ExV valve type (for EVD Emb)
B050
M
B050 - ExV valve type (for EVD EVO)
B051
M
B051 - Enable electronic expansion valve
B052
M
B052 - Factory default installation EVDEVO
48
Bool
1
-
Real
3.0
°C/°F
Real
1.5
°C/°F
Real
8.0
°C/°F
UInt
0
-
USInt
2
-
Bool
0
-
Bool
0
-
USInt
1
-
USInt
0
-
Type
Default
UoM
Bool
-
Int
-
Bool
-
Int
-
Real
6.0
°C/°F
Real
15.0
-
Real
150.0
s
Real
1.0
s
Real
6.0
°C/°F
Real
15.0
-
Real
150.0
s
Real
1.0
s
Real
1.0
°C/°F
Real
10.0
s
Real
1.0
°C/°F
Real
10.0
s
Real
-5.0
°C/°F
Real
5.0
s
Real
-50.0
°C/°F
Real
5.0
s
Real
30.0
°C/°F
Real
15.0
s
Real
20.0
°C/°F
Real
15.0
s
Int
300
s
Int
300
s
Int
300
s
Real
80.0
°C/°F
Real
15.0
s
Int
300
s
Real
-50.0
°C/°F
Int
120
s
Int
80
%
Int
75
%
Real
°C/°F
Int
15
s
Int
0
-
Int
6
s
Int
50
-
Int
480
-
Int
500
-
Int
50
Hz
Int
50
Hz
Int
450
mA
Int
100
mA
Int
30
%
Bool
1
-
Bool
1
-
Bool
0
-
Int
1
-
Int
1
-
Bool
1
-
Bool
0
-
www.euroklimat.it
0: Only serious alarm; 1: All alarms
-99.9...99.9
-99.9...99.9
-99.9...99.9
0: Air;1: Remote air coil; 2: Water
0: Heater; 1: Pumps;2: Heater & pumps
0: Off; 1: On
0: Off; 1: On
1...2
0=CH; 1=HP; 2=CH/HP
Range
0: Off; 1: On
0...9999
0: Off; 1: On
0...9999
LowSH...180°C (324°K)
0.0...800.0
0.0...1000.0
0.0...800.0
LowSH...180°C (324°K)
0.0...800.0
0.0...1000.0
0.0...800.0
-40°C (-72°K)...SH set
0.0...800.0
-40°C (-72°K)...SH set
0.0...800.0
-60°C (-76°K)...MOP set
0.0...800.0
-60°C (-76°K)...MOP set
0.0...800.0
LOP Set...200°C (392°K)
0.0...800.0
LOP Set...200°C (392°K)
0.0...800.0
0...9999
0...9999
0...9999
-60°C (-76°K)...200°C (392°K)
0.0...800.0
0...9999
0...9999
0...9999
0...100
0...100
-999.9...999.9
0...999
0:None; 2: At stop;2: At start; 3: Both
0...999
0...9999
0...9999
0...9999
1...2000
1...2000
0...800
0...250
1...100
0: Off; 1: On
0: Off; 1: On
0: Off; 1: On
0:Custom; 1:Carel E2Vu; 2:Danfoss/Saginomiya
KV; 3:Sporlan ESX; 4:Alco EXM/EXL; 5:Sanhua l
series; 6:Hualu DPF 12V; 7:Hualu SPF 12V;
8:Hualu EPF- VPF 12V
0:Custom; 1:Carel EXV; 2:Alco EX4; 3:Alco EX5;
4:Alco EX6; 5:Alco EX7; 6:Alco EX8 330HZ; 7:Alco
EX8 500Hz; 8:Sporlan SEI 0.5-11; 9:Sporlan SER
1.5-20; 10:Sporlan SEI 30; 11:Sporlan SEI 5;
12:Sporlan SEH 100; 13:Sporlan SEH 175;
14:Danfoss ETS 12.5-25B; 15:Danfoss ETS 50B;
16:Danfoss ETS 100B; 17:Danfoss ETS 250;
18:Danfoss ETS 400; 19:Two Carel EXV; 20:Sporlan
SER(I) G, J, K; 21:Danfoss CCM 10-20-30;
22:Danfoss CCM 40
0: Off; 1: On
0: Off; 1: On
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W