Performance
SKU
HP
1001093976
1/10
Safety Information
DANGER: Do not pump flammable or explosive liquids
such as oil, gasoline, kerosene, ethanol, etc. Do not use in
the presence of flammable or explosive vapors. Using this
pump with or near flammable liquids can cause an
explosion or fire, resulting in property damage, serious
personal injury, and/or death.
DANGER: ALWAYS disconnect the power to the pump
before servicing.
DANGER: Do not touch the motor housing during
operation. The motor is designed to operate at high
temperatures. Do not disassemble the motor housing.
DANGER: Do not handle the pump or pump motor with
wet hands or when standing on a wet or damp surface, or
in water before disconnecting the power.
WARNING: Release all pressure and drain all water
from the system before servicing any component.
WARNING: Secure the discharge line before starting the
pump. An unsecured discharge line will whip, possibly
causing personal injury, and/or property damage.
WARNING: Extension cords may not deliver sufficient
voltage to the pump motor. Extension cords present a life
threatening safety hazard if the insulation becomes
damaged or the connection ends fall into water. The use of
an extension cord to power this pump is not permitted.
GPH of Water @ Total Feet Of Lift
0 ft.
10 ft.
360
318
Installation ..................................................................... 5
Troubleshooting ............................................................ 8
20 ft.
30 ft.
264
198
WARNING: Wear safety goggles at all times when
working with pumps.
WARNING: This unit is designed only for use on 115
volts (single phase),60 Hz, and is equipped with an
approved 3-conductor cord and 3-prong grounded plug. Do
not remove the ground pin under any circumstances. The
3-prong plug must be directly inserted into a properly
installed and grounded 3-prong, grounding-type
receptacle. Do not use this pump with a 2-prong wall
outlet. Replace the 2-prong outlet with a properly
grounded 3-prong receptacle (a GFCI outlet) installed in
accordance with the National Electrical Code and local
codes and ordinances. All wiring should be performed by a
qualified electrician.
WARNING: Protect the electrical cord from sharp
objects, hot surfaces, oil, and chemicals. Avoid kinking the
cord. Do not use damaged or worn cords.
WARNING: Failure to comply with the instruction and
designed operation of this unit may void the warranty.
ATTEMPTING TO USE ADAMAGED PUMP can result in
property damage, serious personal injury, and/or death.
WARNING: Ensure that the electrical circuit to the pump
is protected by a 5-amp minimum (15-amp max.) fuse or
circuit breaker.
CAUTION: Do not lift the pump by the power cord.
2
Max. Lift
40 ft.
132
42 ft.