Important! The fitting must be installed, flushed
and tested after the valid norms!
Operation
The mixer is activated by pulling the lever
handle.
Move to the left = hot water,move to the right =
cold water.
Technical Data
Operating pressure:
Recommended operating pressure:
MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow:
Hansgrohe single lever mixers can be used
together with hydraulically and thermically
controlled continuous flow heaters if the flow
pressure is at least 0,15 MPa.
To adjust the hot water limiter on single lever
mixers, please see page 6.
No adjustment is necessary when using a
continuous flow water heater.
Test certificate
DVGW
14665XXX
X
31665000
X
31763000
X
31666000
32675000
X
Fault
Mixer stiff
Mixer dripping
Hot water temperature too low,
no cold water.
Instantaneous water heater starts
up when cold water is selected.
6
max. 1 MPa
0,1 – 0,5
1,6 MPa
max. 80° C
65° C
ca. 32 l/min 0,3 MPa
P-IX
SVGW
X
X
X
X
X
Cause
-Cartridge defective, calcified
-Cartridge defective,
sedimentation
-Hot water limiter incorrectly set
- Crossflow
English
Spare parts see page 3
1
handle Talis E²
1.1 screw cover
2
handle Metropol S
3
handle Focus S
4
handle Talis S / Talis S²
5
handle Metris S
6
handle Talis Classic
7
handle Focus E²
8
flange
9
flange
10
fixing screw
11
sub plate
12
nut
13
cartridge cpl.
14
locking screw for handle
15
seal
16
screw M5 x 20 (4)
17
noise reduction
18
extension 25 mm
19
extension 22 mm
XXX = Colors
000 chrome plated
820 brushed nickel
880 satin chrome
ACS
NF
WRAS
X
X
X
Remedy
Exchange cartridge
Exchange cartridge
- Set hot water limiter
- Exchange seal (14)
- Exchange O-ring (16x2)
31692000
96338000
14895XXX
31793000
32092000
31093000
14193XXX
98532000
98792XXX
98790XXX
96454000
98793000
98796000
92730000
96059000
95008000
96525000
94073000
13595000
13597XXX
KIWA
X