SW24.D
M1 closing slow down speed
Minimum slow down speed
* with encoder/without encoder
P19
Maximum slow down speed
* with encoder/without encoder
M2 closing slow down speed
Minimum slow down speed
* with encoder/without encoder
P20
Maximum slow down speed
* with encoder/without encoder
M1 motor force
Sets the value of the force given to the motor
to move the gate
P21
Minimum force
Maximum force
M2 motor force
Sets the value of the force given to the motor
to move the gate
P22
Minimum force
Maximum force
M1 acceleration
M1 acceleration ramp until normal speed is
reached
P23
Accelerazione massima
Accelerazione minima
M2 acceleration
M2 acceleration ramp until normal speed is
reached
P24
Accelerazione massima
Accelerazione minima
M1 deceleration ramp
M1 motor deceleration ramp between normal
speed and slow down speed
P25
Soft ramp (minimum deceleration)
Steep ramp (maximum deceleration)
M2 deceleration ramp
M2 motor deceleration ramp between normal
speed and slow down speed
P26
Soft ramp (minimum deceleration)
Steep ramp (maximum deceleration)
Opening delay time between leaves (s)
Minimum delay
P29
Maximum delay
Closing delay time between leaves (s)
Minimum delay
P30
Maximum delay
Number of motors
Single leaf gate
P31
Double leaf gate
Hammer strike
It moves the leaf slightly in the gate movement
opposite direction to make the release of the
electric lock easier
P32
Minimum energizing time (pulse)
Maximum energizing time
Solenoid electric lock energizing time (s)
Hammer strike not active
P33
Hammer strike active
(50)
2nd radio channel function
15 with *
The remote control button associated with the
35 without *
2nd radio channel activates output 12 as an
auxiliary radio output (RAU) for the time set in
75 with *
parameter P21
70 without *
P34
The remote control button associated with the
(50)
2nd radio channel activates the pedestrian
opening. The output 12 functions as a courtesy
15 with *
light (LCO): it is activated when the gate
35 without *
moves and remains active for 100 s after the
gate stops
75 with *
70 without *
Output 12 as auxiliary radio output timer
(RAU)
(5)
P35
1 s (shortest time)
60 s (longest time)
1
Pedestrian opening distance (%)
10
Percentage of the opening total travel by a
pedestrian command
P36
(5)
Shortest pedestrian distance
Maximum distance (full M1 opening)
1
Flashing light during battery operation
10
P37
Flashing light not active in battery operation
Flashing light active during battery operation
(3)
Battery operation mode
Normal operation
1
After an opening command the gate remains
P38
5
open
After the power goes off, the gate opens and
(3)
stays open
Dead-man operation
1
Dead-man not active
Emergency dead-man:
5
- In regular operating conditions, standard
operation
(6)
- If safaties are engaged, dead-man operation
P39
only on input 51 and 52 as per parameter P41
1
setting. Remote controls are disabled
Dead-man active:
8
- step-by-step command disabled, remote
controls disabled. The board accepts open and
(6)
close mantained commands only
Force on mechanical stops
1
Force applied by the motors against the meca-
hanical stops
P40
8
Minimum force (immediate stop detection)
(3)
0
Maximum force (delayed stop detection)
Function of inputs n. 51 and 52 and radio
60
commands
(6)
51: step-by-step or collective command
0
52: pedestrian command
51: open only command
P41
60
52: close only command
(2)
51 & radio command on channel 1: open only
1
command
52 & radio command on channel 2: close only
2
command
Type of actuators used
(OFF)
EIM1 (24 V underground 2 m)
P43
EAM2 (24 V linear 3 m)
EAM3 (24 V linear 4 m)
OFF
ON
(3)
0
10
EN
(PED)
12
PED
(1)
1
60
(100)
0
100
(OFF)
OFF
ON
(0)
0
1
2
(0)
0
1
2
(1)
0
5
(0)
0
1
2
(4)
1
4
5
9