Vimar Giotto 6328 Manual De Instrucciones página 4

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
6328, 6328/C, 6328/CD
The instruction manual is downloadable from the site
EN
www.vimar.com
Video door entry unit type 6328 with 3.5" B/W LCD screen, video door
entry unit type 6328/C with 3.5" colour flat screen and video door
entry unit with 3.5" colour flat screen 6328/CD for hearing impaired
people, are to be used as a supplementary video door entry unit in
2-Wire video door entry kits series 682x.
OPERATION
Carry out connections as described in this leaflet. When entrance
panel push-button is pressed, a call signal is heard on monitor (and
faintly also in the speech unit). The monitor comes on immediately
showing a clear image of the caller. Lift the handset to communicate
with the caller. If , on calling, the handset is already unkooked, the
audio connection is immediately established.
If required operate the electric lock by pressing proper push-button
. The monitor turns off after nearly 30'' (adjustable on the
panel from 30 to 90 seconds). The installation can be switched on by
pressing the push-button with the symbol
ternal view when required.
When two cameras are installed, both cameras are cyclically acti-
vated on pressing the push-button.
Type 6328/CD is designed for use with hearing aids used by hear-
*
ing impaired people. To activate it, select the "T" position on the
hearing aid.
TECHNICAL CHARACTERISTICS OF MONITOR TYPE 6328,
6328/C OR 6328/CD
- Surface wall-mounted monitor in ABS.
- Back plate and expansion plugs or 3 module back box for surface
wall-mounting.
- LCD screen with 3.5'' screen for type 6328, or 3,5" TFT LCD for
type Art. 6328/CD, 6328/C.
- Electronic circuit on interchangeable cards
- Standard video signal CCIR 625 lines - 50 images (6328)
- Standard video signal PAL (6328/C, 6328/CD)
- 4MHz video pass band
- Operating temperature: 0° to +40° C
- Electronic chime
- Input for outdoor call with ton different from the entrance panel call.
- Output for additional chime Art. 860A
- Supply voltage from the bus.
- Input for additional power supply (type 6923), if the installation is
configurated for the simultaneous switching on of two monitors.
- Configuration (through jumpers) to disable the chime from one o
more entrance panel push-buttons.
- Configuration (through jumpers) to block the lock activation when
the monitor is switched off.
- External dimensions: 204x220x71
CONTROLS (Fig. 3, Page 11)
- Chime volume adjustment by means of cursor "A"
- Brightness control: through knob "B"
- Contrast control: through knob "C"
- Push-button for electric lock release
- Autoswitching push-button
- Push-button
for 1st auxiliary service (allows activation of
relais type 682R).
- Pressing push-buttons
auxiliary service and relay type 682R are activated.
- LED for exlusion of chime "D". It lights up with a steady light when
4
, thus allowing an ex-
and
at the same time, the 2nd
the chime has been excluded by using the "A" cursor and it flashes
when there is a conversation in progress on the installation ("en-
gaged" signalling).
- LED for open door "E". When using only an entrance panel the
LED remains lit steadily when the door is open. When two doors
are installed, it remains lit steadily when both door locks are open.
On the contrary if only one of the doors is open, the LED flashes
once for the first door, twice for the second door.
TERMINALS OF MONITOR TYPE 6328, 6328/C OR 6328/CD
1,2)
BUS Line
3,4)
For connection of additional chime type 860A (see variation
1)
12, 13) Additional power supply art. 6923 (terminal 12 = positive)
V3, M) connection for outdoor call push-button.
PROGRAMMING OF MONITOR TYPE 6328, 6328/C OR 6328/CD
5
4
3
2
1
5
4
3
2
1
Monitor identification code
ID1 ID0 MONITOR
ID 0
n°1
ID 1
n°2
n°3
n°4
ID1 ID0 MONITOR
Lock release
n°1
Removing contact 3 from the monitor it is possible to open the door
lock always, with monitor switched off or switched on. Inserting the
jumper, it is possible to release the door lock from the monitor only
n°2
after the call.
n°3
n°4
EN
The operation of monitor
type 6308 is managed by
the 5 contact setting on
the back of monitor. To ac-
tivate the functions insert
or remove the jumpers
supplied with monitor.
Programming must be car-
ried out before powering
the installation.
When on the intallation
1 2 3 4 5
there is more than one
monitor it is necessary to
CH2
identify the monitor with a
different code. The identi-
fication code is assigned
by inserting the jumpers
in contacts 1 and 2 (ID0
CH1
and ID1) as indicated in
the figure.
1 2 3 4 5
ID 0
ID 1
APERTURA SERR
LOCK RELEASE
CH2
CH1
APERTURA SERR
LOCK RELEASE
APERTURA
LOCK REL
APERTURA

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Giotto 6328/cGiotto 6328/cd

Tabla de contenido