Indications for use

The MiniMed™ Mio™ 30 infusion set is
indicated for the subcutaneous infusion of
insulin from an infusion pump.
Replace the infusion set every 48 to 72
hours, or per your healthcare professional's
instructions.
Description
Mio 30 is an angled infusion set with an
integrated insertion device. The built-in legs
support a 30° insertion angle. Mio 30 is
delivered ready for use. Both Mio 30 and the
separate tubing unit are sterile.
Contraindications
Infusion sets are indicated for subcutaneous
use only and not for intravenous (IV) infusion
or the infusion of blood or blood products.
Warnings
■ Do not use if the package has been
opened or damaged. This device is sterile
and non-pyrogenic unless the package
has been opened or damaged. Ensure
sterility by checking that the sterile paper
and tamper-proof seal are not damaged.
■ Inaccurate medication delivery, infection,
or site irritation may result from improper
2
M981721A22A1DOC_A.indb 2
insertion and maintenance of the infusion
site.
■ Carefully remove the needle guard before
inserting the infusion set. Do not bend the
needle prior to insertion, and do not use
the infusion set if the needle is bent or
has been damaged.
■ To avoid accidental needle stick, never
point a loaded insertion device towards
any body part where insertion is not
desired.
■ Do not leave air in the infusion set or the
tubing. Fill them completely.
■ Check frequently to make sure the
cannula remains firmly in place because
you may not feel pain if it pulls out. The
cannula must always be completely
inserted to receive the full amount of
medication.
■ If the infusion site becomes inflamed,
replace the set, and use a new site until
the first site has healed. Replace the
infusion set if the tape becomes loose, or
if the cannula becomes fully or partially
dislodged from the skin.
■ Do not reinsert the introducer needle into
the infusion set. Reinsertion may cause
tearing of the soft cannula, which may
result in unpredictable medication flow.
■ Never fill the infusion set or attempt to
free a clogged tubing while the set is
inserted. You may accidentally deliver too
much medication.
■ Do not put disinfectants, perfumes,
alcohol, or deodorants on the infusion
set as these may affect the integrity of
the set.
■ Put the lid back onto the Mio 30 for safe
disposal.
■ Dispose of the used Mio 30 safely, in a
sharps container, after a single use. Do
not clean or re-sterilize.
■ Reuse of the infusion set may cause
damage to the cannula or needle
and lead to infection, site irritation, or
inaccurate medication delivery.
■ Store Mio 30 infusion sets in a cool,
dry place. Do not leave them in direct
sunlight or inside a vehicle.
■ Use aseptic techniques when temporarily
disconnecting the set and consult
your healthcare provider on how to
compensate for missed medication when
disconnected.
■ When infusing insulin, carefully monitor
your blood glucose levels when
disconnected and after reconnecting.