BIEMMEDUE FJ 16 Manual De Instrucciones página 14

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
starts to heat and produce air flow.
A control circuit linked to the surrounding spacer heater(s) must
therefore be provided.
Warning
The fan's power supply cable must be connected to an
electrical panel equipped with a disconnecting switch to
allow the fan to be switched on and off independently
from the control circuit power supply.
Warning
The power line must be earthed and fitted with a residual
current circuit breaker.
Before connecting the fan to the electrical mains, check that the
mains data correspond to the data shown on the fan's identification
plate.
Warning
The fan is fitted with a temporary power cable, used for
the working test
Warning
The temporary power cable must be removed and replaced
with a H07RN-F cable having a section of at least 1.5
mm
2
: a larger section is required if the cable is more than
15 metres long.
The cable must be stripped, leaving the earth lead at least
2 cm longer.
Warning
For three-phase models, check that the fan's direction of
rotation matches the direction shown on the sticker
located inside the fan body: if it rotates in the opposite
direction, reverse the connection of two of the electrical
power phases.
Warning
ONLY FOR THE FJ 16R TP MODEL
After identifying the necessary fan rotation direction,
connect the motor cables as shown in the following
diagram:
5. OPERATING INSTRUCTIONS
The fan is started and stopped with the selected control circuit.
6. MAINTENANCE
Warning
All of the operations described in this section must be
performed by professionally qualified personnel only.
The following procedures must be done at regular intervals to
ensure efficient operation of the fan. Make sure you have detached
the electrical power line from the fan before starting any work.
L-L 201.02-BM
EN
Warning
Before doing any maintenance:
• Switch off the power supply by means of the cut-off on
the electrical panel;
• Wait for the fan blades to come to a complete stop.
Procedure
Check fan
Clean exterior of the machine
Clean motor and fan
Check electrical connections
6.1. CHECKING THE FAN
Perform the following checks:
• Make sure the machine is not installed in places where there is a
risk of fire or explosion
• Make sure that flammable materials are kept a safe distance away
• Do not use the machine if the safety grilles (motor side and fan
side) have not been remounted
• Make sure that the air intake and outlet are completely
unobstructed,
• Make sure that the machine is not covered by any sheets or
covers;
• Check that the fan is in a fixed and stable position;
• Make sure the fan is constantly monitored during operation and
checked before being started.
6.2 CLEANING THE EXTERIOR OF THE MACHINE
To ensure efficient operation, clean the following parts:
• External body:
• Clean with a cloth.
• Air inlet/outlet:
• Remove all dirt and debris
6.3 CLEANING THE MOTOR AND THE FAN
Clean the fan blades and the motor as follows:
• Remove the fastening screws on the fan safety grille.
• Clean the motor with compressed air.
• Use compressed air to clean inside the cylindrical body of the fan.
• Clean the fan blades with a hard brush.
• Reinstall the safety grille and the fan group.
6.4 CHECKING THE ELECTRICAL CONNECTIONS
After detaching the power cable, check all electrical connections as
follows:
• Make sure that all connections are complete and tight.
• If there are traces of dirt or corrosion, clean or replace the
connections if necessary;
• Replace any damaged wires or connectors if necessary
Warning
After any technical work, always check that the fan works
correctly.
Periodic maintenance
X
X
X
X
14 / 22

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fj 18 mFj 18 tFj 22 mFj 22 tFj 25 mFj 25 t

Tabla de contenido