Storage; Problem Solving - CEVIK PRO6SILENC Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
• In case of malfunction or breakdown, it is not a question of repairing unless you have the
appropriate technical qualifications and tools. Contact one of our technical services, which on
our website www.grupocevik.es.
• Inspect the air system for possible losses, at least once a month, applying soapy water to all
joints. Tighten those you discover that have losses.
• Clean the equipment with a soft brush or with a damp cloth, using a biodegradable solvent.
Do not use flammable liquids such as gasoline or alcohol.
• The air filter is placed in the air inlet of the compressor and helps prevent airborne particles
from entering the compressor and also significantly reduces noise. After being used for long
periods of time the filter must be cleaned. The dirty one makes the entrance reduce the amount
of air. For that reason the filter must be cleaned periodically or replaced regularly:
- Remove the filter cover and replace the old one.
- Replace with a new filter and replace the cover.

STORAGE.

If you need to store the equipment for a long time, then:
1. Turn the pressure switch to the off position.
2. Disconnect the equipment from the electrical contact.
3. Empty the tank through the safety valve.
4. Clean the compressor to remove impurities or dust.
5. Cover the compressor, so that dust does not enter.
6.
Place the compressor in a dry place. Do not place objects on top.
PROBLEMS SOLVING.
Item
Description
1
Power switch does
not work.
2
It starts but it goes
very slow.
3
Loss of air pressure in
the tank or very slow
load.
4
Excessive heating.
5
Any other cause.
Possible cause
Loss of contact in some
electrical connection.
Pressure switch damaged.
The supply voltage is less than
220V.
The tank trap is not closed.
Safety valve is open.
Dirty or clogged air filter.
Fans do not work. Replace fans. Replace fans.
Clogged fans.
Unknown.
32
Solution
Check
all
electrical
connections.
Contact
a
Technical
Service.
Do not use a power cord
extension. Look for an
alternative energy source.
Close the trap.
Check safety valve, if
necessary replace it.
Clean or replace it.
Remove obstruction.
Contact
one
of
our
technical services.

Publicidad

Tabla de contenido
loading

Productos relacionados para CEVIK PRO6SILENC

Tabla de contenido