Technical Characteristics - Nice MOFB Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
6) Maintenance
The photocells do not require any special maintenance work. How-
ever, it is necessary to check them at least once every six months in
order to evaluate their condition (presence of damp, oxides, etc.).
The outer covering and lenses must be cleaned, then testing carried
out again, as described in the previous paragraph. The photocells
have been studied and designed in order that that they will operate
7) Disposal
!
Warning: Some electronic substances may contain polluting
substances - do not dispose of them in the environment.
This product is made from various kinds of material, some of which
can be recycled. Make sure you recycle or dispose of the product in
compliance with laws and regulations locally in force.

8) Technical characteristics

Nice S.p.a., in order to improve its products, reserves the right to modify their technical characteristics at any time without prior notice. In
any case, the manufacturer guarantees their functionality and fitness for the intended purposes.
Note: all technical specifications refer to a temperature of 20°C.
Product type
Technology employed
Power supply/output
Absorbed power
Detection capacity
TX transmission angle
RX reception angle
Adjustability of the MOFOB photocell
Useful capacity
Maximum cable length
Addressing possibility
Use in acid, saline or potentially
explosive atmospheres
Mounting
Protection class for casing
Operating temperature
Dimensions / weight
Nice S.p.a. reserves the right to modify its products at any time.
in normal conditions for at least 10 years. It is, therefore, necessary
to increase the frequency of the maintenance work carried out on the
said photocells after this period of time has elapsed.
Detector for gate and door automation systems (type D according to EN standard 12453),
consisting in a "TX" transmitter and "RX" receiver.
TX-RX direct optical interpolation with modulated infrared ray.
The device can only be connected to "BlueBus" networks, from which it receives its power
supply and sends output signals.
1 "BlueBus" unit.
Opaque objects (larger than 50 mm) located on the optical axis between TX and RX,
which move more slowly than 1.6m/s.
20° +/- 25%
Approximately 20°.
Approximately 30° along the horizontal and vertical axes.
Up to 15m for a maximum TX-RX misalignment of ± 5° (the device can detect and signal
an obstacle even in particularly bad weather conditions).
Up to 50 m.
Up to 7 detectors with the protection function, and 2 with the opening command function.
The automatic synchronism prevents any interference among the various detectors.
No
Vertically wall-mounted
IP55
20 ÷55°C
for MOFB
69 x 78 h 25mm / 50g
for MOFOB 69 x 78 h 37mm / 75g